Electrical Installation RequirementsPower Supply Connection
Installation of this product must conform with local codes
or in the absences of local codes with the current
National Electric Code ANSI NFPA 70 or Canadian
Electrical Codes. WARNING
Cooktop requires a 3-wire 240 volt, 60 hertz, AC circuitTo avoid risk of electrical shock, personal injury, or
protected by a separate 30 amp circuit breaker or timedeath, make sure cooktop has been properly grounded
delay fuse.
and always disconnect it from main power supply
before any servicing.
Junction Box Location
Locate junction box within shaded area. (Figure 4)To avoid risk of electrical shock or personal injury
If installed over Amana ?AOES? or ?AOCS? wall ovens,when connecting copper leads to aluminum house
refer to cooktop over wall oven installation instructions forwiring, use only connectors designed for joining
junction box location.copper to aluminum. Follow connector manufacturer?s
recommendations closely.
Models AK2H30 and AK2H36 Only
To avoid risk of electrical shock or personal injury, do
not ground through neutral wire if installed in mobile
home or if local codes do not permit grounding through
neutral wire.
A
Cooktop has approximately 36 inches of flexible wire
conduit attached to rear of cooktop. (Figure 5) Connect
wire leads extending from conduit to house wires inside
junction box (Junction box not included). Refer to local
Bcodes and attach according to options.
Option 1-United States or Canada
(Cooktop Wire?House Wire)
Bare?Ground (Green)
White?Neutral (White?AK2H30 and AK2H36 Only)
Red?Power Line (Red)
Black?Power Line (Black)
A?9 inches
B?8 inches
Figure 4
6 |