1-1-2. Preparations
Note 1:For details of how remove the cabinet and boards, refer to O2.
DISASSEMBLY�.Pattern box
Note 2:When performing only the adjustments, the lens block and boards
need not be disassembled.
1) Connect the equipment for adjustments according to Fig. 5-1-
2.
1.5m
2) The front panel block (MA-322 board, focus ring, microphone
unit) must be assembled because the focus ring is used for
manual focusing.
Note 3:As removing the cabinet (R) (removing the VC-206 board CN9912)
means removing the lithium 3V power supply (LI-64 board) , data
such as date, time, user-set menus will be lost. After completing
adjustments, reset these data. If the cabinet (R) has been removed,
the self-diagnosis data, data on history of use (total drum rotation
time etc. ) will be lost. Before removing, note down the self-Front of the lens
diagnosis data and the data on history use (data of page: 2, address:
35 to 3D). (Refer to the OService Mode� for the data on the history
use.)
Note 4:Setting the OForced Camera Power ON� Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 01, and press the PAUSE
button of the adjustment remote commander. The above
procedure will enable the camera power to be turned on with
the power switch block (PS-4580) removed. After completing
adjustments, be sure to exit the OForced Camera Power ONFig. 5-1-2.
Mode�.
Note 5:Exiting the OForced Camera Power ON� Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 00, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 0, address: 01, and set data: 00.