aquaAGRIMAC-246379_11_01 7-04-2003 13:10 Pagina 3
OPERATOROS MANUALUK
UNLEADED PETROL: if using unleadedRECOMMENDATIONS:
petrol, you must use a totally synthetic 2-1) Use an efficient suction filter.
stroke engine oil or branded 2-stroke engine2) Ensure suction tube (G) is securely
oil (see table).tightened.
CAUTION: never start the engine with dry3) P45 must never be used for salt water or
other corrosive liquids.
pump as some mechanical parts could be
damaged.
ENSURE ALL MAINTENANCE OR REPAIR
PUMP PRIMING: before starting and if theWORK IS CARRIED OUT BY AN
pump is empty, fill it with water through the
appropriate cap (A). Replace the cap andAUTHORISED SERVICE CENTER.
tighten it.
STARTING:SAFETY:
1) Never re-fuel while the engine is running.
1) Open fuel tap lever (B) by moving toDo not smoke during this operation.
vertical position (open).
2) Set switch to Oon� position OI�, (F).2) Only use the pump in a well ventilated
area.
3) Set the throttle lever (C) to half open3) Never use for pumping inflammable
position.
4) Close the choke lever (D), downwardliquids or acids.
4) Be careful of the hot surfaces on the unit.
position (for cold engine only).
5) Pull the starter rope until the engine fires.
6) As soon as the engine fires once, set theEUROPEAN CONFORMITY INFORMATION
THIS PRODUCT MEETS THE FOLLOWING
choke lever (D) to open position (upward).EUROPEAN DIRECTIVE:
WORKING: the water flow can be adjusted
98/37/CEE MACHINERY (SAFETY)
by setting the throttle lever (C).DIRECTIVE
STOP: switch to stop position OO�.DIRECTIVE 2000/14/CEE (ANNEX V)
DAILY MAINTENANCE:ENGINE OUTPUT(Kw)1,7
1) All residual water must be evacuatedMAX CAPACITY (lt/min)150
through the drainage cap (E) situated onMAX HEAD(m)58
the lower part of the pump. This operationMAX SUCTION HEAD(m)6
must be done regularly as frozen waterENGINE SPEED
would irreparably damage the pump.AT MAX POWER(min-1) 8500
2) Rinse the pump with clean fresh waterGUARANTEED SOUND POWER LEVEL
after use with dirty water (or salted waterLwAav (dBA) (ISO 3744)110
and other liquids, Marinamac / Agrimac).MEASURED SOUND POWER LEVEL
EVERY 20 HOURS: clean and ensure sparkLwAav (dBA) (ISO 3744)108,5
plug gap is 0,5 ? 0,6 mm.
EVERY 40 HOURS:
1) Replace spark plug (champion RDJ8J).
2) Clean air filter, more frequently when
working in dusty conditions.
STORAGE: empty fuel tank and run engine dry.
3 |