Technical Specifications
Dimensions (in cm)Height39,5
Width59,8
Depth27,5
Lighting:2 x 40 W (E14)
Grease filter2
Maximum absorbed power320 W
We reserve the right to generate constructive and chromatic modifications as required by technological growth.
Special accessories
Charcoal filter KLF 60/80E-Nr. 610 899 421
Installation
Unpacking
Check that the cooker hood has no damages.
Transportation damages should immediately be
reported to the one responsible for the transportMin
Min
75 cm
Damages, faults and eventually missing details
43 cm
should immediately be reported to the seller.
Take care of the packing material so that small
children cannot play with it.
Fig. 6
Placement
The hood is to be mounted on the wall.
When installed, the hood must be not less than
43cm. above electric burners or 75 cm. above gas
or mixed-fuel burners (fig. 6).
Electrical connectionElectrical connection
220-240 V - by means of fixed power cable with
Safety warnings for the electrician
plug.
Before connecting the appliance to the power
(Fixed connection of the appliance must only be
supply, check that the voltage indicated on the
carried out by an authorised electrician.)
rating plate corresponds to the mains power supply
available. Appliances fitted with a plug can be
connected to any standard power socket within
easy access.
Should it be necessary to provide a fixed
connection, the hood must only be installed by an
electrician authorised by the local electricity
board. When installing, an omnipolar disconnector
with a distance of at least 3 mm between contacts
must be provided.
The manufacture declines all responsibility for
malfunctions resulting from failure to comply with
the above instructions.