Contact Us
Privacy Notice
Shipping & Returns
Search for Manual:  
 
Search
 
Categories
 ACEC
 ACER
 AEG
 AIKO
 AIWA
 AKAI
 ALBA
 ALFATEC
 ALINCO
 ALNO
 ALPINE
 AMSTRAD
 AOC
 APPLE
 ARTHUR MARTIN ELECTROLUX
 ATAG
 ATLAS-ELECTROLUX
 BANG&OLUFSEN
 BARCO
 BAUKNECHT
 BECKER
 BEKO
 BELINEA
 BLAUPUNKT
 BOSCH
 BOSS
 BRANDT
 BRAUN
 BROTHER
 BUSH
 CANON
 CASIO
 CASTOR
 CLARION
 CLATRONIC
 COMMODORE
 COMPAQ
 CORBERO
 CRATE
 CROSSLEE
 CROWN
 CTX
 CURTISS
 DAEWOO
 DECCA
 DENON
 DIORA
 DOMETIC
 DUAL
 ELECTROLUX
 ELEKTRA
 ELEKTRA BREGENZ
 ELEKTRO HELIOS
 ELITE
 ERICSSON
 ESCOM
 FAURE
 FENDER
 FERGUSON
 FINLUX
 FISHER
 FLYMO
 FRIGIDAIRE
 FUNAI
 GELHARD
 GEMINI
 GOODMANS
 GRAETZ
 GRANADA
 GRUNDIG
 HAMEG
 HANSEATIC
 HARMAN
 HARMAN KARDON
 HEWLETT-PACKARD
 HITACHI
 HUSQVARNA
 HYUNDAI
 IAT
 IGNIS
 INFINITY
 INTEGRA
 ITT
 JBL
 JOHN LEWIS
 JUNO-ELECTROLUX
 JVC
 KAWAI
 KENWOOD
 KODAK
 KOERTING
 KORG
 KUPPERSBUSCH
 LADEN
 LG-GOLDSTAR
 LLOYDS
 LOEWE
 LUX
 LUXMAN
 LUXOR
 M-AUDIO
 MACKIE
 MARANTZ
 MARYNEN
 MATSUI
 MATURA
 MAX-FIRE
 MCCULLOCH
 MEDION
 METZ
 MICROVITEC
 MIELE
 MINOLTA
 MITAC
 MITSUBISHI
 MOFFAT
 MOTOROLA
 MTC
 NAD
 NAKAMICHI
 NEC
 NN
 NOKIA
 NORDMENDE
 NUMARK
 OKI
 ONKYO
 OPTIQUEST
 ORION
 OTHERS
 PACE
 PALLADIUM
 PANASONIC
 PARKINSON COWAN
 PARTNER
 PEACOCK
 PERICOM
 PHILIPS
 PIONEER
 POLAR
 POLAROID
 PRIVILEG
 PROGRESS
 QUELLE
 REVOX
 REX-ELECTROLUX
 RFT
 RICOH
 ROADSTAR
 ROLAND
 ROSENLEW
 ROTEL
 SABA
 SALORA
 SAMSON
 SAMSUNG
 SANGEAN
 SANSUI
 SANYO
 SCHNEIDER
 SEG
 SELECO
 SENNHEISER
 SEPPELFRICKE
 SHARP
 SHERWOOD
 SHURE
 SIEMENS
 SILENTIC
 SONY
 TANDBERG
 TAXAN
 TEAC
 TEC
 TECHNICS
 TELEFUNKEN
 TENSAI
 THERMA
 THOMSON
 THORENS
 TORNADO
 TOSHIBA
 TRICITY BENDIX
 TURBO
 UHER
 UNITRA
 UNIVERSUM
 UNKNOWN
 VIEWSONIC
 VOLTA
 VOSS-ELECTROLUX
 VOX
 WATSON
 WEGA
 WHIRLPOOL
 XER
 ZANKER
 ZANUSSI
 ZOPPAS

CROSSLEE G504FLAMESYSTEM3 Instruction Manual

$4.99

CROSSLEE G504FLAMESYSTEM3 - It's a complete owner's manual ( also known as operating manual or user guide), and it's in PDF format. After placing order we'll send You download instructions on Your email address. See below for delivery information

The manual is available only in language(s): English


Link to manual will be sent on Your email address after You place order.
This product was added to our catalog on Monday 07 May, 2007.
  Reviews  
  Write Review  
  Buy & Download  

Product Reviews
There are currently no reviews for this product.

Other reviews
HIROSHI EMOTO - 11/29/2007 5 of 5 Stars!
Very fast service and a good documents. Thank you.
Mark Tarkett -  5 of 5 Stars!
Excellent service, good price, products are excellent. Will do business with this vendor again.
Adam Solitro - 12/24/2007 5 of 5 Stars!
Hi guys, Thank you for the fast and reliable service that your company offers. Great Work :)
Nadia Yakunina - 06/19/2007 5 of 5 Stars!
It was so difficult to find this manual on the internet - thanks a lot for making it so easy and simple. Incredibly handy. AND. It looks you make so many people happy for such small money. Good job!
Jeff Lewis - 07/24/2006 5 of 5 Stars!
Received the Hitachi user manual. Happy happy happy! Thanks again.

Customers who bought this product also purchased
CROSSLEE 010202000081F.S.2 Owner's Manual
CROSSLEE 010202000081F.S.2 Owner's Manual
CROSSLEE LFX6H Owner's Manual
CROSSLEE LFX6H Owner's Manual
CROSSLEE 010204116280FS4 Owner's Manual
CROSSLEE 010204116280FS4 Owner's Manual
CROSSLEE 010208950241F.S.1 Owner's Manual
CROSSLEE 010208950241F.S.1 Owner's Manual
CROSSLEE 010202016084F.S.3 Owner's Manual
CROSSLEE 010202016084F.S.3 Owner's Manual
CROSSLEE SV847-031284715310 Owner's Manual
CROSSLEE SV847-031284715310 Owner's Manual

Click to see text excerpt from the manual
Checking Operation of Fire
Turn on the gas supply at the meter and to the appliance at the isolating cock. Purge the air from the appliance. Press and
turn the gas control anti-clockwise, keep the control fully depressed. The igniter will operate and the pilot will light, check
that the electrode is sparking to the head of the pilot burner, continue until a pilot ignition is established. 0nce a pilot-
flame has been established; keep the control depressed for a further 20 seconds. Release the gas control and check that the
pilot remains lit. Depress the control knob slightly and rotate anti-clockwise until the index symbol is aligned with the
LOW symbol on the indicator label. Release and rotate the control knob to the high position (HIGH symbol) and allow
the appliance to run for a period of approximately 5 minutes, check for satisfactory flame picture prior to carrying out the
spillage test.
To check the gas pressure at the appliance, allow the coals and the coal bed to cool and turn off the gas supply at the
isolating cock, remove the hexagon headed screw and connect a manometer to the pressure test point. Turn on the gas and
ignite the fire, allow to heat up and check that the gas pressure is 20 +/- 1 mbar any appreciable drop may indicate losses
through pipework. The pressure test point may also be used to check for leakag?OFFe of t?he joints to the appliance. Turn
the gas supply to the fire, remove the pressure gauge, replace the screw and then turn the gas supply 'ON'. Fit the fire
front.
Turn the gas control to the OFF position, wait for 90 seconds, fully depress the gas control, turn to the ignition position
and release the control. Attempt to light the pilot with an already prepared match or taper. If the plot lights the FSD is
faulty.
Spillage Check
The appliance should be run on high setting for at least 5 minutes prior to the test with the front and fret located in
position. The test must be carried out with all windows and doors of the room closed, if an extractor fan is situated in the
room, this test should be repeated with the fan running. If there is a connected room with an extractor fan, the test should
be repeated with all the doors to that room opened and the extractor fan running. All smoke must be drawn into the flue.
If spillage occurs, allow a further 10 minutes. Should spillage still occur examine the chimney for the fault and rectify.
Check for satisfactory clearance of products by positioning a lighted smoke match central to the opening 120mm down
from the canopy and level with the rear edge of the front simulated coal. See Fig. 6A.
Demonstrate the lighting and extinguishing procedures to the user.
Advise that:
The curing effect of heating the coals will cause an initial odour which, although not harmful, may require additional
ventilation until the odour has disappeared.
Any debris or soot is cleaned from the appliance. Advise the customer that they should read their Users Instructions
before operating the fire and always follow the advice in the section headed `Removal of Debris or Soot Deposits'. The
appliance must be serviced annually by a competent person in accordance with these instructions.
Advise that the appliance is fitted with an Oxy-pilot to prevent continued operation in the event of spillage occurring if
the fire sh?OFFuts? repeatedly the appliance must be turned off and not used until an expert is consulted. The Oxy-pilot
must not be adjusted or rendered inoperable and replacements must only be the manufacturers supplied part.
Complete the section in the enclosed registration leaflet. Advise that any component part of this appliance be guaranteed
against defective workmanship or faulty materials for a period of twelve months from the date of purchase.
Any such part will be replaced free of charge on ?s areceddripess at of tthe the purcoschast of er postage only, provided
that:
" It is accompanied by the registration section cut out of the booklet, together with the original purchase receipt, which
will be returned with the replacement part.
" Any installation, repairs or adjustments have been carried out by a compete?s nt person, such as the supplier
representative or a CORGI registered installer.
Page 8
Shopping Cart more
0 items
Log In
Reviews more
Write ReviewWrite a review on this product!
Payments
PayPal
PayPal
Information
Shipping & Returns
Privacy Notice
Conditions of Use
List of Manuals
Contact Us
What's New? more
RD-XS30B
RD-XS30B
Quick Start

$4.99
Current Parse Time: 0.169 s with 42 queries. Queries took 0.018668