2-3-6. FLD Grid Test Display
2-3-6-1. Transition Keys in Self Check Mode
Y DVD MENU ? RIGHT, LEFT ? [TEST GRID] ?
RETURN
2-3-6-2. Operation and Display
Only the first grid of FLD is lit, and the grids are switched over
sequentially by entering the RIGHT or LEFT on the remote com-
mander. The grids are switched to 1-2-3 direction at the input of
RIGHT on the remote commander, while they are switched to 3-
2-1 direction at the input of LEFT on the remote commander. This
test checks whether each grid makes indication individually.
Display at the start of Grid Test
? (Input in RIGHT direction)
2-3-7. LED Test Display
2-3-7-1. Transition Keys in Self Check Mode
Y DVD MENU ? RIGHT, LEFT ? [TEST LED] ?
RETURN
Y SHUTTLE on the main unit and the remote commander during
LED Test display
2-3-7-2. Operation and Display
Grids are switched over sequentially according to the input of
RIGHT or LEFT on the remote commander.
FLD display during LED Test
2-3-8. Beep Sound Test
2-3-8-1. Transition Keys in Self Check Mode
Y Input of a key on the set during key test
2-3-8-2. Operation and Display
In the Self Check mode, each time a key on the main unit is en-
tered, a beep sound of 2 kHz (100 ms) is generated.