DVP-S315
SECTION 6
TEST MODE
6-1. Starting up Test Mode
Syscon Diagnosis
IF con Ver. 0.620 (9315)
With the DVP-S315 turned off, press [TITLE], [CLEAR], and SYScon Ver. 0.400 (0000)
[POWER] keys on the Remocon in this order, and the Test mode
Select Sub No. ; 02 -? Enter item No.[02]
will start up and the Test Mode Menu as shown in Figure 1 will** Press Remocon Key **
appear on the video display.SIRCS:FF KEY:FF
Test Mode MenuFigure 4
0. Syscon Diagnosis
1. Drive Auto Adjustment
2. Drive Manual Operation
3. Mecha AgingSyscon Diagnosis
IF con Ver. 0.620 (9315)
4. Emergency History SYScon Ver. 0.400 (0000)
5. Other Checks
Exit: POWER keySelect Sub No. ; 02 - 0? Enter item No.[02-0]
** Press Remocon Key **
SIRCS:FF KEY:FF
Figure 1
Figure 5
In the Test mode, use all keys on the Remocon or operation panel
when performing necessary operation. In any menu except during
test with the Syscon Diagnosis menu, press the [POSyscon DiagnosisWER] key to
exit from the Test mode, and return to the power of IF con Ver. 0.620 (9315)f status.
Pressing [0] key on the Remocon during display of this initial menu SYScon Ver. 0.400 (0000)
activates the Diagnosis mode and the screen as shoPress Enter wn in Figure 2; 02 - 02? Enter item No.[02-02]
appears.** Press Remocon Key **
SIRCS:FF KEY:FF
Syscon Diagnosis
IF con Ver.? IFcon version (checksum)Figure 6
SYScon Ver.? Syscon version (checksum)
(checksum of Syscon isUp to here, the [CLEAR] key can be used. Pressing [CLEAR] key
initially 0000)clears the selected number, and selection can be retried from the
Model No. DPX11????? Model codebeginning. If [ENTER] key is pressed, the diagnosis of only the
** Press Remocon Key **
selected number is executed, and the result is displayed.
SIRCS:FF KEY:FF
If any key is pressed while the result display is blinking, the screen
Figure 2returns to the initial Test Mode Menu screen. Where visual check
is necessary such as a still picture check, or when an error oc-
6-2. Selection of Check Itemcurred, use [PREV] key for repeated checking. To go to the next
step, press [NEXT] key.
A check item can be selected when Model No. is displayed. Press
numeric keys to check the selected item, or any key other than
If the diagnosis of selected number does not exist, the initial screen
numeric keys to check all items.is restored when [ENTER] key is pressed.
6-2-1. Selected Item Check
6-2-2. All Items Check
As the menu is not displayed, select the number from the list, and
Press any key other than numeric keys when Model No. is dis-
enter 2-digit main item No. and 2-digit sub item No. using nu-played to activate the all items check mode. In the all items check
meric keys on the Remocon. When the first one digit is entered,
mode, RAM check is simplified. In concrete, only the skipped
the item selection screen is displayed. Then, enter remaining threeblocks such as 0-ff, 500-5ff, a00-aff, f00-fff, 1400-14ff, ... (ad-
digits and press [ENTER] key.
dresses) are checked. Check is executed from the top item of the
When an item is selected, the detail check is executed where indiagnosis check items list sequentially. In a checking where visual
the case of RAM check, all addresses are checked twice by chang-
check is not necessary, check progresses to the next item auto-
ing the data.matically unless an error occurs.
<Example> Select 2-2 ROM Check.
In case of an error or visual check is necessary, press [PREV] key,
As item No. is <2-2>, enter O0202�.and the item concerned is repeatedly checked. To go to the next
Syscon Diagnosisitem, press [NEXT] key.
IF con Ver. 0.620 (9315)
SYScon Ver. 0.400 (0000)
Select Diag No. ; 0 -? Enter item No.[0]
** Press Remocon Key **
SIRCS:FF KEY:FF
Figure 3
6-1 |