2-3-4. Communication Monitoring Display
The communication state is monitored and displayed while the
key name on the main unit and the remote commander is displayed.
W hen the communication to the System Controller failed, VIDEO
CD, DVD, and CD segments turn on.
Communication error display (at no key input)
VCD;DigitalGROUP TITLE TRACK CHAP INDEX ANGLE NTSC HOURMINSEC
PROGRESSIVE MULTIDVD
MP 3REPEAT1
CDSHUFFLEPGMA-B
Communication error display (at code display without input of
the remote commander)
VCD;DigitalGROUP TITLE TRACK CHAP INDEX ANGLE NTSC HOURMINSEC
PROGRESSIVE MULTI
DVD
MP 3REPEAT1
CDSHUFFLEPGMA-B
2-3-5. FLD Anode Test Display and SHUTTLE Click
Operation Test
2-3-5-1. Transition Keys in Self Check Mode
Y? on the main unit and the remote commander
Y SHUTTLE on the remote commander during Anode Test dis-
play
(This model does not provide JOG/SHUTTLE, and therefore
use another DVD remote commander having the JOG/
SHUTTLE)
2-3-5-2. Operation and Display
The Self Check mode transits to this mode w? key is en-hen
tered. Only the first segment of each grid of FLD turns on, and
each time the SHUTTLE is entered, the segment of each grid is
switched in order. When SHUTTLE input is clockwise, the seg-
ment switches in 1 ? 2 ? 3 direction, or counterclockwise it
switches in 3 ? 2 ? 1 direction. This tests whether each segment
turns on individually.
Display at the start of Anode Test
VCD;DigitalGROUP TITLE TRACK CHAP INDEX ANGLE NTSC HOURMINSEC
PROGRESSIVE MULTIDVD
MP 3REPEAT1
CDSHUFFLEPGMA-B
? (Input in CW direction)
VCD;DigitalGROUP TITLE TRACK CHAP INDEX ANGLE NTSC HOURMINSEC
PROGRESSIVE MULTIDVD
MP 3REPEAT1
CDSHUFFLEPGMA-B
6-16 |