DVP-NS15/NS51P/NS43P/NS53P/K56P
SECTION 6
TEST MODE
6-1. EXECUTING IOP MEASUREMENT(5) Wait until a hexadecimal number appear.
Manual Adjust
In order to execute IOP measurement, the following standard
procedures must be followed.
1. Track Balance Adjust:
2. Track Gain Adjust:
(1) In standby mode, press [TOP MENU], [CLEAR], [POWER] to
3. Focus Balance Adjust:
enter Remocon Diagnosis Mode.4. Focus Gain Adjust:
5. Eq Boost Adjust:
Remocon Diagnosis Menu6. Iop. ED:
7. TRV. Level:
0. External Chip Check8. S curve(FE) Level:
1. Servo Parameter Check9. RFL(PI) Level:
2. Drive Manual Operation0. MIRR Time:
3. Emergency History
4. Version information$4 Change Value
5. Video Level Adjustment[RETURN] Return to previous menu
Model: xxx xxx xxx
IF-con Ver : xxx(6) Convert data from hexadecimal to decimal.
Syscon Ver : xxx
(7) Use the following formula to calculate IOP in mA
IOP (mA)=IOP (decimal) x 0.622678.
(2) Select ?2. Drive Manual Operation? by pressing the 2 key on
the remote commander. The screen will appear as below.
(8) Press [RETURN] to return back to previous menu.
Drive Manual Operation
(9) Press - to return to Top Menu and power OFF the DVD
Player.
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment6-2. EMERGENCY HISTORY CHECK
4. Tray Aging Mode
0. Return to top Menu
Information of Emergency History.
(3) Select ?3. Manual Adjustment? by pressing the 3 key on the(1) In standby mode, press [TOP MENU], [CLEAR], [POWER] to
enter Remocon Diagnosis Mode.
remote commander. The screen will appear as below.
(2) Select ?3. Emergency History?.
Manual Adjust
1. Track Balance Adjust:Emg. History Check
2. Track Gain Adjust:
3. Focus Balance Adjust:Laser HoursCD999h 59min
4. Focus Gain Adjust:DVD999h 59min
5. Eg boost Adjust:
6. Iop:1. 01 05 04 0400 92 46 00
7. TRV. Level:00 00 00 0000 00 23 45
8. S curve(FE) Level:
9. RFL(PI) Level:2. 02 02 01 0100 A9 4B 00
0. MIRR Time:00 00 00 0000 00 23 45
$4 Change Value[Next] Next Page [Prev] Prev Page
[RETURN] Return to previous menu- Return to Top Menu
(3) Laser Hours
(4)Select Iop by pressing 6 key on the remote commander.
DVD Laser ON time. (Total ON time)
CD Laser ON time. (Total ON time)
(4) Emergency History
The history information from last ?1? to ?10? can be scrolled
with [NEXT] key or [PREV] key.
(5) Error code
Example of Error code
1. 01 05 04 0400 92 46 00
00 00 00 0000 00 23 45
6-1 |