6-12. MECHANISM TEST MODEY O1. All (DiscCheck On)�
This is the overall aging mode (with disc check).ADJUSTMENT
Contents of the aging operations are as follows. Table and tray are
moved in the following sequence: TableClose (DiscNumber Ran-
Y Introduction
dom) ? ChuckUp ? DiscCheck ? TableEx Open ? TrayExMoveThe mechanism test mode is designed for mechanism check. Do
(Left ? Right) ? TableExClose ? ChuckDown ? TableOpen. A
series of operation as described above is called as one full count,not use this mode for purposes other than the mechanism check.
and is repeated.
6-12-1. How to enter the mechanism test mode
While the machine is in the standby mode, press the keys on the
Y O2. All (DiscCheck Off)�remote commander in the order starting from [TITLE] ? [CLEAR]
This is the overall aging mode (without disc check).
Contents of the aging operations are as follows. Table and tray are? [POWER] to enter the remote commander service mode. Then
press the numeric key [3] and select O3. Mecha Test Mode�.
moved in the following sequence: TableClose(DiscNumber
Random) ? ChuckUp ? TableExOpen ? TrayExMove(Left ?
Right) ? TableExClose ? ChuckDown ? TableOpen. A series of6-12-2. Types of the mechanism test mode
When you enter the mechanism test mode, the following menu
operation as described above is called as one full count, and is
repeated.appears.
### Mecha Test Mode ###Y O3. Table�
This is the table aging mode.
Please Select Test Mode
Contents of the aging operations are as follows. Table is rotated in
the following sequence: TableClose(Tray NoMove) ? ChuckUp1. Aging
? TableExOpen ? TableExClose ? ChuckDown ? TableOpen.
2. Check
3. VoltageA series of operation as described above is called as one full count,
and is repeated.
Y O4. Tray�
This is the tray aging mode.
Contents of the aging operations are as follows. Tray is rotated one_
Exit: RETURN
full turn in the clockwise direction and is rotated one full turn in the
counter-clockwise direction. One full rotation of tray is called as
Press the desired numeric number on the display. Then you enter
one full count, and is repeated. The disc number is reduced by onethe selected mode.
after every 20 counts.
When O1. Aging� is selected, you enter the mechanism aging mode.
When O2. Check� is selected, you enter the mechanism check mode.
3-1-2. Setting number of times of aging
When aging mode is selected, the following menu appears. Set theWhen O3. Voltage� is selected, you enter the voltage check mode.
number of times of aging in this menu.
6-12-3. Description of Each Mode### Mecha Aging ###
3-1. Mechanism aging modeInput Aging Count
This is the aging mode for mechanism. When this mode is selected,Input Max : 65535
the mechanism is initialized first.No Input : Infinity
_
3-1-1. Selection of aging mode
When initialization is completed, the following menu appears. Se-
lect the desired aging mode from the following menu.
### Mecha Aging ###
Exit: RETURN
Please Select Aging Mode
Use the numeric keys to enter the desired number. Then press
[ENTER] to set the number. If you press [ENTER] without entering1. All (DiscCheck On)
2. All (DiscCheck Off)
any number, the number of times of aging becomes infinite.3. Table
4. Tray
_
Exit: RETURN
When you select the desired numeric number on display, the corre-
sponding aging mode will be selected.
6-22 |