1-4. CAMERA SYSTEM ADJUSTMENT1. HALL Adjustment
For detecting the position of lens iris, adjust the HALL AMP
Before perform the camera system adjustments, check that thegain and offset.
specified values of OVIDEO SYSTEM ADJUSTMENTS� are
satisfied.ModeSTILL
SubjectNot required
Data setting during camera system adjustment
Perform the following data setting before the camera system ad-Measurement PointDisplayed data of page: 1 (Note 2)
justments.Measuring InstrumentAdjusting remote commander
Adjustment PageF1) Select page: 0, address: 01, and set data: 01.
2) After writing down the original data of the following addresses,
Adjustment Address2E, 2F, 34, 35input the following data.
Specified Value13 to 17 during IRIS OPEN
PageAddressData7B to 7F during IRIS CLOSE
E4310
Note 1:Check that the data of page: 6, address: 02 is O00�.
E8F00
If not, turn the power of unit OFF/ON.B6700
Note 2:The right two digits of the page: 1 displayed data of the
Note:Press the pause button of the adjusting remoteadjusting remote commander.
commander each time to set data.1:00:XX
After completing the camera system adjustments, release theDisplayed data
data setting:
1) Select page: 0, address: 01, and set data: 01.Adjusting method:
2) Select the above address, and input the orignal data writen1) Select page: 0, address: 01, and set data: 01.
down at step 2).2) Select page: 5, address: F1, and set data: FF.
Note:Press the pause button of the adjusting remote3) Select page: D, address: 63, set data: 40, and press the PAUSE
commander each time to set data.button of the adjusting remote commander.
3) Select page: 0, address: 01, and set data: 00.4) Perform OData setting dring camera system adjuatment�.
5) Select page: 6, address: 94, and set data: 15.
6) Select page: 6, address: 95, and set data: 7D.
7) Select page: 6, address: 01, set data: 6D, and press the PAUSE
button. (The HALL adjustment is performed and the adjustment
data is stored in page: F, address: 2E, 2F, 34 and 35)
8) Select page: 6, address: 02, and check that the data is O01�.
9) Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
Checking method:
1) Select page: 0, address: 03, and set data: 03.
2) Select page: 6, address: 01, set data: 01, and press the PAUSE
button of the adjusting remote commander.
3) Select page: 1, and check that the displayed data (Note 2) during
IRIS OPEN satisfies the specified value.
4) Select page: 6, address: 01, set data: 03, and press the PAUSE
button.
5) Select page: 1, and check that the displayed data (Note 2) during
IRIS CLOSE satisfies the specified value.
Processing after Completing Adjustments:
1) Select page: 0, address: 03, and set data: 00.
2) Select page: 6, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
3) Select page: 6, address: 95, and set data: 00.
4) Select page: 6, address: 94, and set data: 00.
5) Select page: 5, address: F1, and set data: 00.
6) Select page: D, address: 63, set data: 00, and press the PAUSE
button.
7) Release the data setting performed at step 4).
8) Select page: 0, address: 01, and set data: 00.
5-13 |