DSC-P92
1-1-2. Preparations
1) Connect the equipment for adjustments according to Fig. 6-1-4.Pattern box
2) Start up the application for adjustment (SEUS).
Note1: Setting the OForced Power ON Mode (Forced STILL Mode)�
1) Select page: 00, address: 01, and set data: 01.
2) Select page: 2F, address: 21, and write data: 03.
The above procedure will enable the power (STILL mode) toAbout 29cm
be turned on with POWER switch (SY-93 board CN705)
disconnected. After completing adjustments, be sure to exit the
OForced Power ON Mode�.
Note2: Setting the OForced Power ON Mode (Forced PLA�Y Mode)
1) Select page: 00, address: 01, and set data: 01.
2) Select page: 2F, address: 21, and write data: 04.
The above procedure will enable the power (PLAY mode) to be
turned on with POWER switch (SY-93 board CN705)Front of the lens
disconnected. After completing adjustments, be sure to exit the
OForced Power ON Mode�.
Note3: Exiting the OForced Power ON Mode�
1) Select page: 00, address: 01, and set data: 01.
2) Select page: 2F, address: 21, and write data: 00.
3) Select page: 00, address: 01, and set data: 00.Fig. 6-1-2.
1-1-3. Discharging of the flashlight power supply
The capacitor which is used as power supply of flashlight is charged
with 200V to 300V voltage. Discharge this voltage before starting
adjustments in order to protect service engineers from electric shock.
Discharge procedure
1. Remove the power supply (AC power adaptor or battery).
2. Fabricate the discharging jig as shown in Fig. 6-1-3 locally by
yourself. Connect the discharging jig to the positive (+) and
negativ�e) terminal of the flash v (oltage charge capacitor. Allow
ten seconds to discharge the voltage.
Capacitor
Shorting jig
ST-82 BOARD
(1k & / 1w)
Fig. 6-1-3.
6-4 |