1-6. ERROR3. Adjustment Time Out
In case of an error during the execution of adjustment, the Auto-
matic Adjustment Program interrupts the processing at that point,
and displays an error message, and then terminates the program
execution there.This part indicates
the adjustment
1-6-1. Error Messageitem in which
an error occurred.
W hen an error message is displayed, perform the remedy given
below, and then retry adjustment. If the error message is displayed
Fig. 6-1-56
though the remedy was performed, the circuits will be faulty.
SymptomAdjustment does not finish within the specified
1. Connect Error
time.
Cause? Adjustment conditions are wrong.
? Data error exists in the camera.
Remedy? Check that the conditions such as a subject
are correct.
? Reset the camera.
4. Adjustment NG
Fig. 6-1-54
SymptomUSB communication with the set is abnormal.
Cause? USB cable is not inserted tightly.
This part indicates
? Power supply is not installed correctly.the adjustment
? Communication with SEUS is abnormal.
item in which
Remedy? Disconnect the USB cable once, and then re-an error occurred.
connect it tightly and check that the set is in
OUSB Mode�.Fig. 6-1-57
? Install the power supply correctly.
? Start the SEUS and click the [Connect] toSymptomThe adjusted data does not become the speci-
check that the connection state is established.fied value.
Cause? Adjustment conditions are wrong.
? Data error exists in the camera.
2. RESET the CAMERA and Try AgainRemedy? Check that the conditions such as a subject
are correct.
? Reset the camera.
Fig. 6-1-55
SymptomThe camera is not ready for adjustment.
Cause? Data error exists in the camera.
Remedy? Reset the camera.
DSC-P200
6-23 |