6. AWB 3200K-5800K Standard Data Input6) A picture captured by the camera is displayed on the screen,
[Adjustment method]and the adjustment and checking are performed.
1) Start the Color Adjustment Program (N1ColorAdjustment.exe).
2) Click the [Connect] button to set the camera to the adjust-
ment mode.
Fig. 6-1-37
Note:If the following message is displayed, the picture frame
Fig. 6-1-35setting is faulty. Check the picture frame, and then perform
readjustment.
3) Adjust the mode switch of the camera to ?CAMERA? and set
MACRO mode. Shoot the 9 colors chart with the zoom at WIDE
end.
4) Adjust the camera direction and distance to set the picture
frame. (Refer to 3. Picture Frame Setting)
5) Click the [AWB 3200-5800K Standard Data Input] button.
Fig. 6-1-38
7) Upon successful completion of the adjustment, the following
message is displayed. Click the [OK] button.
Fig. 6-1-36
Fig. 6-1-39
DSC-N1_ADJ
6-21 |