14. Strobe Light Level and White Balance Check15. CCD Defect Compensation
Check the light level regulation and the white balance wModehen theSTILL
strobe light flashes.
SubjectClear chart
ModeSTILL
(25 cm from the front of the lens)
SubjectA plate which reflection rate is 18%(Note1)
(1.0m from the front of the lens)
Adjustment PageB
(Note1)
Adjustment Address88 to AF
Measurement PointDisplay data of page: 1
Measuring Instrument Adjustment remote commanderNote 1:Check that there are no dust, no dirt and no reflection on the clear
chart.
Specified valueY level data: 68 to A9 (Note4)
Note 2:Any subject other than the clear chart should not be in the screen.
R-Y data: FA to FF or 00 to 06 (Note5)
B-Y data: FA to FF or 00 to 06 (Note5)
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
Note 1:Perform this adjustment in the dark room or use a dark box.
2) Select page: B, address: 88 to AF, and input data: FF to each
Note 2:Any light other than the strobe light should not light up the plate.
address.
Note 3:This adjustment should be carried out upon completion of
Note:Press the PAUSE button of the adjustment remote commander
OHALL Adjustment�, OFlange Back Adjustment�, OLight Level
Adjustment�, OAuto White Balance Adjustment� and OStrobe Whiteeach time to set the data.
Balance Adjustment�.3) Turn the power of the unit OFF and then ON.
Note 4:Display data of page 1 of the adjustment remote commander4)Wait until the camer.a picture appear on the screen.
1 : 00 : XX5) Select page: 0, address: 01, and set data: 01.
Y level data6) Select page: E, address: 52, after noting down the data, set
Note 5:Display data of page 1 of the adjustment remote commander.
data: 50, and press the PAUSE button of the adjustment remote
1 : XX : XX
commander.
B-Y data
7) Select page: F, address: AF, after noting down the data, set
R-Y data
data: B3, and press the PAUSE button.
8) Select page: 5, address: F1, and set data: FF.
Checking method:
9) Select page: 6, address: 2C, and set data: 01.
1) Select page: 0, address: 01, and set data: 01.
10) Select page: 6, address: 93, and set data: A0.
2) Select page: E, address: 52, after noting down the data, set
11) Select page: 6, address: 01, set data: 79, and press the PAUSE
data: 0E, and press the PAUSE button of the adjustment remote
button.
commander.
12) Select page: 6, address: 6C, and set data: 01.
3) Select page: 5, address: F1, and set data: FF.
13) Select page: 6, address: 01, set data: 8D, and press the PAUSE
4) Select page: 6, address: 10, and set data: 58.
button.
5) Select page: 6, address: 2C, and set data: 01.
(The CCD defect compensation is performed and the
6) Select page: 6, address: 92, and set data: 00.
adjustment data is stored in page: B, address: 88 to AF.)
7) Select page: 6, address: 93, and set data: A0.
14) Select page: 6, address: 02, and check that the data changes to
8) Select page: 6, address: 01, set data: 79, and press the PAUSE
O01�.
button.
9) Select page: 6, address: 01, set data: 67, and press the PAUSE
Processing after Completing Adjustments:
button.
1) Select page: E, address: 52, set the data noted down at step 6),
10) Check the flashing of the strobe light.
and press the PAUSE button.
11) Select page: 0, address: 03, and set data: 01.
2) Select page: F, address: B3, and set data: 60, and press the
12) Select page: 1, and check that the Y level data satisfies the
PAUSE button.
specified value. (Note4)
3) Select page: F, address: AF, set the data noted down at step 7),
13) Select page: 0, address: 03, and set data: 02.
and press the PAUSE button.
14) Select page: 1, and check that the R-Y data and B-Y data satisfy
4) Select page: 6, address: 01, and set data: 00, and press the
the specified value respectively.(Note5)
PAUSE button of the adjustment remote commander.
5) Select page: 6, address: 2C, and set data: 00.
Processing after Completing Adjustments:
6) Select page: 6, address: 6C, and set data: 00.
1) Select page: E, address: 52, set the data noted down at step 2),
7) Select page: 6, address: 93, and set data: 00.
and press the PAUSE button.
8) Select page: 5, address: F1, and set data: 00.
2) Select page: 6, address: 10, and set data: 00.
9) Select page: 0, address: 01, and set data: 00.
3) Select page: 6, address: 2C, and set data: 00.
4) Select page: 6, address: 93, and set data: 00.
5) Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
6) Select page: 5, address: F1, and set data: 00.
7) Select page: 0, address: 03, and set data: 00.
8) Select page: 0, address: 01, and set data: 00.
5-27 |