7. Light Level Adjustment and ND Shutter Check8. Mixed Color Cancel Adjustment
Adjust the standard LV value.To perform mixed color cancel adjustment based on data of each
color in color bar.
ModeSTILL
SubjectClear chartModeSTILL
(Color reproduction adjustment frame)SubjectColor bar chart
Measurement PointDisplayed data of page: 1 (Note 2)(Color reproduction adjustment frame)
Adjustment PageF
Measuring Instrument Adjusting remote commander
Adjustment PageFAdjustment Address A0 to A3
Adjustment Address26, 28Note 1:PerforOm Light Level Adjustment� before this
Specified ValueAE level 1: 0FE0 to 1020adjustment.
AE level 2: Below 1100Note 2:Check that the data of page: 6, address: 02 is O00�.
If not, turn the power of the unit OFF/ON.
Note 1:Check that the data of page: 6, address: 02 is O00�.
If not, turn the power of the unit OFF/ON.Adjusting method:
Note 2:The right four digits of the page: 1 displayed data of the1)Select page: 0, address: 01, and set data: 01.
adjusting remote commander.2)Select page: 5, address: F1, and set data: FF.
1:XX:XX3)Select page: D, address: 63, set data: 40, and press the PAUSE
ççç Displayed databutton of the adjusting remote commander.
4)Select page: 6, address: 01, set data: D7, and press the PAUSE
Adjusting method:button.
1)Select page: 0, address: 01, and set data: 01.5)Select page: 6, address: 01, set data: D5, and press the PAUSE
2)Select page: 5, address: F1, and set data: FF.button. (The mixed color adjustment is performed and the
3)Select page: D, address: 63, set data: 40, and press the Padjustment daAUSEta is stored in page: F, addresses: A0 to A3)
button of the adjusting remote commander.6)Select page: 6, address: 02, and check that the data is O01�.
4)Select page: 6, address: 01, set data: 0D, and press the PAUSE
button. (The light level adjustment is perforPrmed and the ad-ocessing after Completing Adjustments:
justment data is stored in page: F, addresses:1) 26 and 28)Select page: 6, address: 01, set data: 00, and press the PAUSE
5)Select page: 6, address: 02, and check that the data is O01�.button of the adjusting remote commander.
6)Select page: 0, address: 03, and set data: 06.2)Select page: 5, address: F1, and set data: 00.
7)Select page: 1, and check that the displayed data (Note 2)3)Select page: D, address: 63, set data: 00, and press the PAUSE
satisfies the AE level 1 specified value.button.
8)Select page: E, address: 41, set data: 6B, and press the P4)Select page: 0, address: 01, and set data: 00.AUSE
button.
9)Select page: 6, address: 1C, and set data: 03.
10) Select page: 1, and check that the displayed data (Note 2)
satisfies the AE level 2 specified value.
Processing after Completing Adjustments:
1)Select page: 6, address: 1C, and set data: 00.
2)Select page: E, address: 41, set data: 6A, and press the PAUSE
button of the adjusting remote commander.
3)Select page: 0, address: 03, and set data: 00.
4)Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
5)Select page: 5, address: F1, and set data: 00.
6)Select page: D, address: 63, set data: 00, and press the PAUSE
button.
7)Select page: 0, address: 01, and set data: 00.
5-18 |