D-E888/E999/EJ825/EJ925
5.Error Rate Check Display
The C1 Error Rate Check Display mode becomes active if the fol-
lowing operation is performed during the operation in the normal
mode.
1) Make sure that the Power is not turned on.
2) Fix the open/close detection switch (S801) on the Main board
with a tape so that the switch is turned on.
Or, short the solder bridge at the TAP802 (OPEN) on the Main
board (see Fig. 2 on page 4).
3) Turn the Power on, then set the CD to activate the Play mode.
4) Short the solder bridge at the TAP801 (TEST) on the Main
board (see Fig. 2 on page 4).
5) Press the [DISPLAY] button on remote commander, and the
C1 Error Rate Check Display mode becomes active, and the
remote commander LCD displays the following.
OK is displayed when the error rate is 0 to 99/7350, or NG is
displayed when over 100/7350.
Remote commander LCD display (OK display)
--- 00 00
Remote commander LCD display (NG display)
--- 11 11
The remote commander LCD displays the following when no
data is read such as in the skip mode.
Remote commander LCD display
--- ---:--
Note:Press again the [DISPLAY] button on remote com-
mander, and the remote commander LCD displays the
time counted down from total time of CD.
Press once mor[DISPLAY]e the button on remote com-
mander, and the remote commander LCD returns to
the display of the music being played at present.
6) Turn the Power off.
7) Open the solder bridges at the TAP801 (TEST) and TAP802
(OPEN) on the Main board.
Note: Remove the solder completely.
5 |