8. White Balance Adjustment (PD-118 board)
Correct the white balance.
If deviated, the LCD screen color cannot be reproduced.
ModeCamera
SubjectArbitrary
Measurement Point
Check on LCD display
Measuring Instrument
Adjustment PageD
Adjustment AddressA8, A9
The LCD screen should not be
Specified Value
colored.
Note 1:Check the white balance only when replacing the fol-
lowing parts. If necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC5501
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: A8 and A9, and set the data to the
initial value.
Note:To write in the non-volatile memory (EEPROM), press
the PAUSE button of the adjustment remote commander
each time to set the data.
AddressData
A880
A980
3) Check that the LCD screen is not colored. If colored, change
the data of page: D, address: A8 and A9 so that the LCD screen
is not colored.
Note: To write in the non-volatile memory (EEPROM), press
the PAUSE button of the adjustment remote commander
each time to set the data.
4) Select page: 0, address: 01, and set data: 00.