DCR-TRV60/TRV60E/TRV70
12. LV Standard Data Input
Adjust the normal coefficient of the light value.
SubjectClear chart
(Color reproduction adjustment frame)
Measurement PointDisplay data of page 1 (Note5)
Measuring Instrument Adjustment remote commander
Adjustment PageF
Adjustment Address1A, 1B
Specified Value0FE0 to 1020
Note1: This adjustment should be carried out upon completion of OColor
Reproduction Adjustment�.
Note2: The data of page: 0, address: 10 must be O00�.
Note3: Check that the data of page: 6, addrO00�. If not, turn ofess: 02 is f
the power and turn on again.
Note4: Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Display data
Switch setting:
1) POWER.................................................................. CAMERA
2) NIGHT SHOT ..................................................................OFF
3) FOCUS.................................................................. MANUAL
4) DIGITAL ZOOM (Menu setting) ....................................OFF
Adjusting method:
Order Page Address DataProcedure
100101Set the data.
2Wait for more than 6 sec.
364001Set the data, and press PAUSE
button.
46010D Set the data, and press PAUSE
button.
5602Check that the data changes to
O01�. (Note5)
60031E Set the data.
71Check that the display data (Note5)
satisfies the specified value.
Note5: The adjustment data will be automatically input to page: F, address:
1A, 1B.
Processing after Completing Adjustments
Order Page Address DataProcedure
160100Set the data, and press PAUSE
button.
264000Set the data.
300300Set the data.
400100Set the data.
6-31 |