12. Angular Velocity Sensor Output Check and13. CCD Defect Check RadarWRadarWRadarWRadarWRadarW
Steadyshot Check RadarWRadarWRadarWRadarWRadarW
ModeCAMERA
Check the angular velocity sensor output.
SubjectNot required
Precautions on the Parts ReplacementMeasurement PointCheck on the monitor TV
There are two types of repair parts.
Measuring Instrument
Type AENC03JA
Note: Check that the data of page: 0, address: 10 is O00�.
Type BENC03JB
Replace the broken sensor with a same type sensor. If replace with
Checking method:
other type parts, the image will vibrate up and down or left and
right during hand-shake correction operations.Order Page Address DataProcedure
160105 Press PAUSE button.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care261FCC
as if it dropped, the balance of the oscillator will be disrupted and364003
operations will not be performed properly.
Check on the monitor screen
4
that no defect is found.
ModeCAMERA
564004
SubjectNot required
Check on the monitor screen
Measurement PointDisplayed data of page: 1 (Note 2)6
that no defect is found.
Measuring Instrument Adjusting remote commander
Specified valuePITCH data: 2680 to 5080Processing after completing adjustment:
YAW data: 2680 to 5080
Order Page Address DataProcedure
Note 1:Check that the data of page: 0, address: 10 is O00�.
Note 2:The right four digits of the page: 1 displayed data of the160100 Press PAUSE button.
adjusting remote commander.264000
1:XX:XX
361F00
Displayed data
Switch setting:
1) ZOOM .....................................................................TELE end
2) STEADYSHOT (Menu setting)........................................ ON
Checking method:
Order Page Address DataProcedure
PITCH sensor output check (SE752 of SI-041 board)
100311
W ith the set in still state,
check that the displayed data
21
(Note 2) satisfies the PITCH
data specified value.
YAW sensor output check (SE751 of SI-041 board)
300312
W ith the set in still state,
check that the displayed data
41
(Note 2) satisfies the YAW
data specified value.
500300
Steadyshot operation check
Shake the set vertically and
horizontally to check that the
6
steadyshot function operates
normally.
6-27 |