4-3. SERVICE MODE2. Emergence Memory Address
Additional note on adjustment2-1. C Page. Emergence Memory Address
Note: After the completion of the all adjustments, cancel the service modePage CAddress 38 to 43
by either of the following ways.
1) After data on page: D and F is restored, unplug the main power
supply and remove the coin lithium battery. ( In this case, daAddressteContents
and time and menu setting have been set by users ar38e canceledEMG code w.hen first error occurs
Perform resetting.)
2) After data on page: D and F is restored, select page: 0, address:3AUpper: MSW code when shift starts when first error
01, and return the data to 00. And when data on page:2 and 3 aroccurse
changed, return data to the original condition.Lower: MSW code when first error occurs
3BLower: MSW code to be moved when first error
1. Setting the Test Modeoccurs
3CEMG code when second error occurs
Page FAddress 2C3EUpper: MSW code when shift starts when second
error occurs
DataFunctionLower: MSW code when second error occurs
00Normal3FLower: MSW code to be moved when second error
01Test modeoccurs
Various emergency prohibitions and releases40EMG code when last error occurs
Drum emergency, capstan emergency, loading motor42Upper: MSW code when shift starts when last error
emergency, reel emergency, tape top and end, DEW
detectionoccurs
Lower: MSW code when last error occurs
43Lower: MSW code to be moved when last error
Page DAddress 10occurs
When no error occurs in this unit, data O00� is written in the above
DataFunction
00Normaladdresses (38 to 43). when first error occurs in the unit, the data
corresponding to the error is written in the first emergency address
01Forced camera power ON(38 to 3B). In the same way, when the second error occurs, the data
02Forced VTR power ONcorresponding to the error is written in the second emergency address
03Forced camera + VTR power ON(3C to 3F).
Finally, when the last error occurs, the data corresponding to the
Y Before setting the data , select page: 0, address: 01, and set data:error is written in the last emergency address (40 to 43).
Note :After completing adjustments, be sure to initialize the data of
01.addresses 38 to 43 to O00�.
Y For page D and F, the data set will be recorded in the non-volatile
memory by pressing the PAUSE button of the adjustment remote
commander. In this case, take note that the test mode will not beInitializing method:
1) Select page: 0, address: 01, and set data: 01.
exited even when the main power is turned off (8.4Vdc).2) Select page: C, address: 38, set data: 00, and press the PAUSE
Y After completing adjustments/repairs, be sure to return the databutton.
of this address to 00, and press the PAUSE button of the adjustment
remote commander. And select page: 0, address: 01, and set data:3) Select address: 39 to 43 and set data O00� into them in the
same way as address: 38.
00.4) Select page: 0, address: 01, and set data: 00.
5-73 |