DCR-TRV255E/TRV260/TRV265/TRV265E
2. Flange Back Adjustment RadarWRadarWRadarWAdjusting method:
(Using the Minipattern Box)
Order Page Address DataProcedure
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be de10viated dur01 - 01
ing auto focusing/manual focusing.264801
360113 Press PAUSE button.
ModeCAMERA
460127 Press PAUSE button. (Note 7)
SubjectSiemens star chart with ND filter for
minipattern box (Note 1)Check the data changes to
5602
O01�.
Measurement PointCheck operation on monitor TV
Note 7:The adjustment data will be automatically input to page:
Measuring Instrument
F, address: 44 to 54.
Adjustment PageF
Adjustment Address44 to 54Processing after completing adjustment:
Note 1:Dark Siemens star chart.
Order Page Address DataProcedure
Note 2:Check that the data of page: 0, address: 10 is O00�.
160100 Press PAUSE button.
Note 3:Check that the data of page: 6, address: 02 is O00�.
If not, turn the power of unit OFF/ON.260125 Press PAUSE button.
Note 4:Perform the adjustment with the camcorder in horizon-360100 Press PAUSE button.
tal state.
464800
Note 5:Perform OHALL Adjustment� before this adjustment.
500100
Switch setting:Perform OFlange Back
6
1) NIGHTSHOT PLUS ........................................................OFFCheck�.
2) DISPLAY (Menu setting)...............................................LCD
Preparations before adjustments:
1) The minipattern box is installed as shown in the following fig-
ure.
Note 6:The attachment lenses are not used.
2) Install the minipattern box so that the distance between it and
the front of lens of camcorder is less than 3 cm.
3) Make the height of minipattern box and the camera equal.
4) Check the output voltage of the regulated power supply is the
specified voltag? 0.01 e Vdc.
5) Check that the center of Siemens star chart meets the center of
shot image screen with the zoom lens at TELE end and WIDE
end respectively.
Specified voltage: The specified voltage varies according to the
minipattern box, so adjust the power supply
output voltage to the specified voltage written
on the sheet which is supplied with the
minipattern box.
Below 3 cm
Minipattern box
Camcorder
Camera
table
Regulated power supply
Output voltage : Specified voltage ?0.01 Vdc
Output current : more than 3.5 A
Red (+)
Black (�)
Yellow (SENS +)
White (SENS �)Need not connected
Black (GND)
Fig. 6-1-7
6-16 |