1-1-2. Preparations
Note 1:For details of how remove the cabinet and boards, refer to O2.
DISASSEMBLY�.Pattern box
Note 2:When performing only the adjustments, the lens block and boards
need not be disassembled.
1) Connect the equipment for adjustments according to Fig. 5-1-2.
Note 3:As removing the cabinet (R) (removing the VC-260 board CN009)
means removing the lithium 3V power supply (BT8301), data such1.5 m
as date, time, user-set menus will be lost. After completing
adjustments, reset these data. If the cabinet (R) has been removed,
the self-diagnosis data, data on history of use (total drum rotation
time etc. ) will be lost. Before removing, note down the data of
page: 2, address: A2 to AA (data on history of use) and the data of
page: 2, address: B0 to C6 (self-diagnosis data). (Refer to O5-
4.Service Mode� for the data on the history use and the self-
diagnosis data.)Front of the lens
Note 4:Setting the OForced Camera Power ON� Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 01, and press the PAUSE
button of the adjustment remote commander.
The above procedure will enable the camera power to be turned
on with the control switch block (PS-1700) removed. After
completing adjustments, be sure to exit the OForced Camera PowerFig. 5-1-2.
ON Mode�.
Note 5:Exiting the OForced Camera Power ON� Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 00, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 0, address: 01, and set data: 00.