DCR-TRV12E/TRV14E/TRV19/TRV19E
2-2. MSW Code
MSW when errors occur:
Information on MSW (mode SW) when errors occur
MSW when movement starts:
Information on MSW when movements starts when the mechanism position is moved (When the L motor is moved)
MSW of target of movement:
Information on target MSW of movement when the mechanism position is moved
Mechanical Position
? UNLOADLOAD ?
EJBLULEBLSRBLHLBLSTOPBLR/P
0100=41110=E0110=61110=E0010=21110=E1010=A1110=E1000=81110=E1100=C
? A (MSB)
? B
? C
? D (LSB) (Fixed at O0�)
LS chassis movement section
Lock releasedPinch roller pressing
Cassette compartment
PositionCodeContents
EJ4Position at which the cassette component lock is released, at the farthest unload side mechanically
at which the mechanism can move no further in the UNLOAD direction.
BLEBLANK code, at the boundary between codes.
EJECT completion position. when the cassette is ejected, the mechanism will stop at this position.
ULE6Cassette IN standby. The guide will start protruding out as the mechanism moves towards the
LOAD position.
SR2Position at which it is possible to release the S ratchet.
HLAGuide loading are performed here.
STOP8Stop position in the loading state. The pinch roller separates, the tension regulator returns, and the
brake is imposed on both reels.
PB, REC, CUE, REVIEW, PAUSE, FF, REW positions. When pinch roller is pressed, and the tension
R/PCregulator is ON, the mechanism is operating at this position in modes in which normal images are
shown.
NULL0Code not existing in the MD. Default value.
FStatus before finding any mechanism position.
6-51 |