3. HALL Adjustment
For detecting the position of the lens iris, adjust AMP gain and
offset.
SubjectNot required
Measurement PointDisplay data of page 1 (Note1)
Measuring Instrument Adjustment remote commander
Adjustment PageF
Adjustment Address17, 18, 19
Specified Value 115 to 19
Specified Value 288 to 8C
Note1: Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
IRIS display data
Switch setting:
POWER.................................................................. CAMERA
Adjusting method:
Order Page Address DataProcedure
100101Set the data.
269417Set the data.
36958A Set the data.
46016D Set the data, and press PAUSE
button.
5602Check that the data changes to
O01�. (Note2)
660100Set the data, and press PAUSE
button.
Note2: The adjustment data will be automatically input to page: F, address:
17, 18, 19.
Checking method:
Order Page Address DataProcedure
160403Set the data.
260101Set the data, and press PAUSE
button.
31Check that the IRIS display data
(Note1) satisfies the specified
value 1.
460103Set the data, and press PAUSE
button.
51Check that the IRIS display data
(Note1) satisfies the specified
value.2.
Processing after Completing Adjustments:
Order Page Address DataProcedure
169400Set the data.
269500Set the data.
360100Set the data, and press PAUSE
button.
460400Set the data.
500100Set the data.
5-17 |