6. Flange Back Check
SubjectSiemens star
(2.0m from the front of the lens)
(Luminance : approx. 200 lux)
Measurement PointCheck operation on TV monitor
Measuring Instrument
Specified ValueFocused at the TELE end and WIDE
end.
Note1: The data of page: 0, address: 10 must be O00�.
Switch setting:
1) POWER....................................................... CAMERA-TAPE
Note2: When the auto focus is ON, the lens can be checked if it is focused
or not by observing the data on the page 1 of the adjustment remote
commander.
1) Select page: 0, address: 03, and set data: 0F.
2) Page 1 shows the state of the focus.
1 : 00 : XX
Odd: Focused
Even: Unfocused
Checking method:
1) Select page: 6, address: 40, and set data: 01.
2) Select page: 6, address: 41, and set data: 01.
3) Place the Siemens star 2.0m from the front of the lens.
4) To open the IRIS, decrease the luminous intensity to the
Siemens star up to a point before noise appear on the image.
5) Shoot the Siemens star with the zoom TELE end.
6) Turn on the auto focus.
7) Check that the lens is focused (Note2).
8) Select page: 6, address: 21, and set data: 10.
9) Shoot the Siemens star with the zoom WIDE end.
10) Observe the TV monitor and check that the lens is focused.
Processing after Completing Adjustments:
1) Select page: 6, address: 21, and set data: 00.
2) Select page: 6, address: 40, and set data: 00.
3) Select page: 6, address: 41, and set data: 00.
4) Select page: 0, address: 03, and set data: 00.
DCR-PC53E/PC55/PC55E
6-24 |