2. Bright Adjustment (VC-210 board)3. Contrast Adjustment (VC-210 board)
Set the level of the VIDEO signal for driving the LCD to the specifSet the level of the iedVIDEO signal for driving the LCD to the specified
value. If deviated, the screen image will lose sharpness,value. If de or will beviated, the screen image will lose sharpness, or will be
blackish or saturated (whitish).blackish or saturated (whitish).
ModeCameraModeCamera
SubjectArbitrarySubjectArbitrary
Measurement Point4Pin of CN2904 (EVF VG)Measurement Point4Pin of CN2904 (EVF VG)
Measuring Instrument OscilloscopeMeasuring Instrument Oscilloscope
Adjustment PageDAdjustment PageD
Adjustment Address7AAdjustment Address7B
Specified ValueA = 7.2 ? 0.05VSpecified ValueA = 1.85 ? 0.05V
Adjusting method:Adjusting method:
1) Select page: 0, address: 01, and set data: 01.1) Select page: 0, address: 01, and set data: 01.
2) Select page: 3, address: 0C, set data: 20, and pr2) Select pagess the PAeUSE: 3, address: 0C, set data: 20, and press the PAUSE
button of the adjustment remote commander.button of the adjustment remote commander.
3) Select page: 3, address: 22, set data: 02, and pr3) Select pagess the PAeUSE: 3, address: 22, set data: 02, and press the PAUSE
button of the adjustment remote commander.button of the adjustment remote commander.
4) Select page: D, address: 7A, change the data and set the v4) Select page: D,oltage address: 7B, change the data and set the voltage
(A) between the reversed waveform pedestal and non-re(A) between the 3-steversedp peak and pedestal to the specified value.
waveform pedestal to the specified value.5) Press the PAUSE button of the adjustment remote commander.
5) Press the PAUSE button of the adjustment remote commander6) Select pag.e: 3, address: 22, set data: 00, and press the PAUSE
6) Select page: 3, address: 22, set data: 00, and prbutton of the adjustment remote commanderess the PAUSE.
button of the adjustment remote commander.7) Select page: 3, address: 0C, set data: 00, and press the PAUSE
7) Select page: 3, address: 0C, set data: 00, and prbutton of the adjustment remote commanderess the PAUSE.
button of the adjustment remote commander.8) Select page: 0, address: 01, and set data: 00.
8) Select page: 0, address: 01, and set data: 00.
Pedestal
A3 step peak
A
2H2H
PedestalPedestal
Fig. 5-1-13Fig. 5-1-14
5-19 |