DCR-PC103E/PC104E/PC105/PC105E
1-1-2. Preparations
Note1: For details of how remove the cabinet and boarO2.ds, refer to Pattern box
DISASSEMBLY �.
Note2: When performing only the adjustments, the lens block and boards
need not be disassembled.
Note3: Before performing the adjustments, check the data of page: 0,
address: 10 is O00�. If not, set data: 00 to this address.
1.5 m
1) Connect the equipment for adjustments according to Fig. 6-1-3.
Note4: As removing the control switch block (FK4400) (removing
CN1019 of the VC-319 board) means removing the lithium 3V
power supply (BT6401 on the LI-070 board), data such as date,
time, user-set menus will be lost. After completing adjustments,
reset these data.
But the self-diagnosis data and the data on history of use (total
drum rotation time etc.) will be kept even if the lithium 3V power
supply is removed. (RefO6-4. Serer to vice Mode� for the self-Front of the lens
diagnosis data and the data on history of use.)
Note5: Setting the OForced Camera Power ON� Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 01, and press the PAUSE
button.
The above procedure will enable the camera power to be turnedFig. 6-1-2.
on with the control switch block (PS4400) removed. After
completing adjustments, be surOFe to eorced Camera Poxit the wer
ON Mode�.
Note6: Exiting the OForced Camera Power ON� Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 00, and press the PAUSE
button.
3) Select page: 0, address: 01, and set data: 00.
6-5 |