DCR-PC103E/PC104E/PC105/PC105E
3. HALL AdjustmentProcessing after Completing Adjustments:
Order Page Address DataProcedure
For detecting the position of the lens iris and ND filter, adjust AMP160100Set the data, and press PAUSE
gain and offset.button.
SubjectNot required
200300Set the data.
Measurement PointDisplay data of page 1 (Note1)300100Set the data.
Measuring Instrument Adjustment remote commander
Adjustment PageF
Adjustment Address13 to 18, 92
Specified Value 1D4 to DC
Specified Value 224 to 2C
Specified Value 3D2 to DE
Specified Value 422 to 2E
Note1: Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
IRIS display data
ND display data
Note2: The data of page: 0, address: 10 must be O00�.
Switch setting:
POWER.................................................................. CAMERA
Adjusting method:
Order Page Address DataProcedure
100101Set the data.
26016D Set the data, and press PAUSE button.
3602Check that the data changes to
O01�. (Note3)
460100 Set the data, and press PAUSE button.
Note3: The adjustment data will be automatically input to page: F, address:
13 to 18, 92.
Checking method:
Order Page Address DataProcedure
100303Set the data.
260101 Set the data, and press PAUSE button.
360103 Set the data, and press PAUSE button.
41Check that the IRIS display data
(Note1) satisfies the specified
value 1.
560101 Set the data, and press PAUSE button.
61Check that the IRIS display data
(Note1) satisfies the specified
value 2.
76016B Set the data, and press PAUSE button.
860169Set the data, and press PAUSE
button.
91Check that the ND display data
(Note1) satisfies the specified
value 3.
106016B Set the data, and press PAUSE button.
111Check that the ND display data
(Note1) satisfies the specified
value 4.
6-23 |