[SERVICE POSITION TO CHECK THE VTR SECTION]
Connection to Check the VTR Section
To check the VTR section, set the VTR to the OForced VTR power ON� mode. (Or, connect the contr CN402 ol switch block (PS-2850) to the
of ME-020 board and set the power switch to the OVIDEO� position.)
Operate the VTR function using the adjustment remote commander (with the HOLD switch set in the OFF position).
Setting the OForced VTR Power ON� modeExiting the OForced VTR Power ON� mode
1) Select page: 0, address: 01, and set data: 01.1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 02 and press the P2) Select paAgUSEe: D, address: 10, data: 00, and press the PAUSE
button of the adjustment remote commander.button of the adjustment remote commander.
3) Select page: 0, address: 01, and set data: 00.
When exiting the Forced VTR Power ON mode, connect the control
switch block (PS-2850) to the CN402 of ME-020 board. Or,
when ejecting the cassette, connect the control switch block (PS-1770)
to the CN402 of ME-020 board. and press the EJECT switch.
Control switch block
Adjustment remote
(PS-2850) (10P)
commander (RM-95)
ME-020 board
CPC-6 terminal board jig
(J-6082-371-A)
Mechanism deck
CPC-6 flexible jig
VC-284 board(J-6082-370-B)
Control switch block
(FK-2850)
BJ-003 board
DC-IN connector
AC power
AC IN
adaptor
2-13 |