9. MAX GAIN Adjustment10. Auto White Balance & LV Standard Data Input
Setting the minimum illumination.SubjectClear chart (Color bar chart standard
If it is not consistent, the image level required for taking subjects inpicture frame)
low illuminance will not be produced (dark).Adjustment PageF
SubjectClear chart (Color bar chart standard
Adjustment Address20 to 23, 3E, 3F
picture frame)
Measurement PointDDS display of LCD or monitor TV
Note 1:Perform OColor Reproduction Adjustment� before this adjustment.
Measuring Instrument (Note)Note 2:Check that the data of page: 6, address: 02 is 00. (If the data is
O01�, turn the power of the unit OFF/ON.)
Adjustment PageF
Adjustment Address2C
Adjusting method:
Specified Value78 to 881) Select page: 0, address: 01, and set data: 01.
2) Wait for two seconds.
Note:The right two digits of the display data of the LCD or monitor 3)Select pagTV ise: 6, address: 01, set data: 11, and press the PAUSE
the object data. If the data change so swiftly that it cannot be readbutton of the adjustment remote commander.
out, record the data on a tape once and play the tape back in the
4) Select page: 6, address: 01, set data: 0D, and press the PAUSE
frame still mode and obtain the average data.button of the adjustment remote commander.
CAM 00 0000
CAM 00 00XX(When the standard data is take in, the data will be automatically
Object datainput to address: 20 to 23, 3E, 3F.)
5) Select page: 6, address: 02, and check that the data is O01�.
Switch setting:6) Perform OAuto White Balance Adjustment�.
1) STEADY SHOT (Menu display) .....................................OFF
Processing after Completing Adjustments:
Adjusting method:1) Select page: 6, address: 01, set data: 00, and press the PAUSE
1) Select page: 0, address: 01, and set data: 01.button of the adjustment remote commander.
2) Select page: 0, address: 01, and set data: 00.
2) Select page: D, address: 11, and set data: 02, and press the
PAUSE button of the adjustment remote commander.
3) Select page: 6, address: 04, and set data: 01.
4) Select page: 6, address: 40, and set data: 02.
5) Select page: 6, address: 10, and set data: 02.
6) Select page: 6, address: 01, set data: 19 and press the PAUSE
button of the adjustment remote commander.
7) Select page: F, address: 2C, change the data and adjust the DDS
display data to the specified value. (Note)
8) Press the PAUSE button of the adjustment remote commander.
Processing after Completing Adjustments:
1) Select page: D, address: 11, set data: 00, and press the PAUSE
button of the adjustment remote commander.
2) Select page: 0, address: 01, and set data: 00.
3) Select page: 6, address: 01, and set data: 00, and press the
PAUSE button of the adjustment remote commander.
4) Select page: 6, address: 04, and set data: 00.
5) Select page: 6, address: 40, and set data: 00.
6) Select page: 6, address: 10, and set data: 00.
5-15 |