DCR-IP5/IP5E/IP7BT/IP7E
4-3. SERVICE MODE
1. Setting the Test Mode
Page DAddress 10
DataFunction
00Normal
01Forced camera power ON
02Forced VTR power ON
03Forced camera + VTR power ON
05Forced memory power ON
Y Before setting the data, select page: 0, address: 01, and set data:
01.
Y For page D and F, the data set is recorded in the non-volatile
memory by pressing the PAUSE button of the adjustment remote
commander. In this case, take note that the test mode will not be
exited even when the main power is turned off.
Y After completing adjustments/repairs, be sure to return the data
of this address to 00, and press the PAUSE button of the adjustment
remote commander. And select page: 0, address: 01, and set data:
00.
2. Emergence Memory AddressInitializing method:
Page CAddress 20 to 2BOrder Page Address DataProcedure
100101Set the data.
23F601Set the data and press PAUSE
AddressContents
button.
20EMG code when first error occurs33F6Check that the data changes to
Upper: MSW code when shift starts when first
22error occursO00�.
Lower: MSW code when first error occurs400100Set the data.
Lower: MSW code to be moved when first error
23occurs2-1.EMG Code (Emergency Code)
Codes corresponding to the errors which occur are written in
24EMG code when second error occursaddresses 20, 24 and 28. The type of error indicated by the code are
Upper: MSW code when shift starts when secondshown in the following table.
26error occurs
CodeEmergency Type
Lower: MSW code when second error occurs
Lower: MSW code to be moved when second error00No error
27occurs10Loading motor emergency during loading
28EMG code when last error occurs11Loading motor emergency during unloading
Upper: MSW code when shift starts when last error20T reel emergency during unloading
2Aoccurs21S reel emergency during unloading
Lower: MSW code when last error occurs22T reel emergency during normal rotation
Lower: MSW code to be moved when last error
2Boccurs23S reel emergency during normal rotation
31FG emergency of the capstan
32Emergency during reverse rotation of the capstan
When no error occurs in this unit, daO00� is written in the abota v40eFG emergency at the start up of the drum
addresses (20 to 2B). When first error occurs in the unit, the data41PG emergency at the start up of the drum
corresponding to the error is written in the first emergency address
(20 to 23). In the same way, when the second error occurs, the data42FG emergency during normal rotation of the drum
43PG emergency during normal rotation of the drum
corresponding to the error is written in the second emergency address
(24 to 27).
Finally, when the last error occurs, the data corresponding to the
error is written in the last emergency address (28 to 2B).
Note: After completing adjustments, be sure to initialize the data of
addresses 20 to 2B to O00�.