[SERVICE POSITION TO CHECK THE CAMERA SECTION]
Connection to Check the Camera Section
To check the CAMERA section, set the CAMERA to the OForced camera power ON� mode.
To obtain the focus manually, connect both of the FP-538 board and the FP-539 board.
Setting the OForced Camera Power ON� modeExiting the OForced Camera Power ON� mode
1) Select page: 0, address: 01, and set data:1) Select page: 01. 0, address: 01, and set data: 01.
2) Select page: 0, address: 10, and set data:2) Select page: 00. 0, address: 10, and set data: 00.
3) Select page: D, address: 10, set data: 01, and 3) Select page: D, address: 10, set data: 00, and press
press the PAUSE button of the adjustment remote the PAUSE button of the adjustment remote commander.
commander.4) Select page: 0, address: 01, and set data: 00.
Cabinet (rear) block assembly
CD-406 board
CN1000
Control switch block
Lens block assembly(SS-2980)
Must be connected.
CN452
(CPC)
FP-542 flexible boardCN2020DI-087 board
CN461DI-087 board
CN463CN2019DC-098 board
CN001CN458
CN456
CN455
CN451
VC-308 board
CN457
DC-IN connector
CN453
Mechanism deck
Adjustment remote
commander (RM-95)
LANC jackAC power
adaptor AC IN
ST-076 board
CN4201
Cabinet (F) block assembly
FP-538 board
This wire must be connected
to obtain the focus manually.
FP-539 board
2-19 |