14. Picture Frame Setting (All white frame)Processing after Completing Adjustment:
Reset the data setting after the adjustment finished.
SubjectClear chart (All white frame)
Order Page Address DataProcedure
(1 m (PTB-450) or 40 cm (PTB-
1450) from the front of lens)160100 Press PAUSE button.
Measurement PointVideo terminal of A/V OUT jac26k or9000
A/V jack (75 & terminated)369100
Measuring Instrument Monitor TV469200
Only the clear chart must be shot
Specified Value569300
(entire screen is white).
Note 1:Check that the data of page: 0, address: 10 is O00�.
Note 2:The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX : XX
XL or YL data
XH or YH data
Switch setting
1) POWER .............................................CAMERA-TAPE mode
2) NIGHTSHOT PLUS ........................................................OFF
3) DIGITAL ZOOM (Menu setting)....................................OFF
4) STEADY SHOT (Menu setting).....................................OFF
5) FOCUS...................................................................MANUAL
6) WIDE SELECT..................................................................4:3
Setting method:
Order Page Address DataProcedure
W hile observing the TV
monitor screen, adjust the
zoom to TELE side from
1
WIDE side, and stop it when
the black frame of the chart
disappears.
Check that whole of the
2
screen is white.
300318
Read XH data and XL data.
41
(Note 2)
500322
Read YH data and YL data.
61
(Note 2)
700300
In the following adjustment,
if the OAll white frame� is
8
used, adjust the clear chart to
this position.
How to release the zoom and focus when they deviated:
If the zoom and focus deviated due to some reason, reset them in
the following method.
Order Page Address DataProcedure
1690XL
2691XH
3692YL
4693YH
560179 Press PAUSE button
DCR-HC39E/HC41/HC42/HC42E/HC43/HC43E
6-33 |