ENGLISHENGLISHJAPJAPANESEANESE
1-2. SELF-DIAGNOSIS FUNCTION
1.SELF-DIAGNOSIS FUNCTION2.SELF-DIAGNOSIS DISPLAY
When problems occur while the unit is operating, the self-diagnosisWhen problems occur while the unit is operating, the counter of the
function starts working, and displays on the vieviewfwfinderinder or LCD screen consists of an alphabet and 4-digit number, or LCD,
screen what to do. This function consists of twwhico display; self-h blinks at 3.2Hz. This 5-character display indicates the
diagnosis display and service mode display.Orepaired by:�, Oblock� in which the problem occurred, and Odetailed
Details of the self-diagnosis functions are provided in the Instrcode� of the problem.uction
manual.
Viewfinder or LCD screen
C : 1 3 : 0 0
Blinks at 3.2Hz
C1 30 0
Repaired by:BlockDetailed Code
C : Corrected by customer Indicates the appropriateSelf-diagnosis Code Table.
H : Corrected by dealerstep to be taken.
E : Corrected by serviceE.g.
engineer13....Faulty disc is used.
Note: The Oself-diagnosis display� data will be kept even if the lithium battery (CK-146 board BT5401 of the cabinet (R) assembly) is removed.
3.SELF-DIAGNOSIS CODE TABLE
Self-diagnosis Code
BlockDetailedSymptom/StateCorrection
FunctionCode
Repaired by:
C0400Non-standard battery is used.Use the InfoLITHIUM battery.
C1300Faulty disc is used.Use a compatible disc with the camcorder.
C2100Condensation.Remove the disc, and insert it again after one hour.
E2000EEPROM data are rewritten.Make EEPROM data correct value. (Note)
Inspect the lens block focus MR sensor (Pin 1, 2 of CN1501 of
Difficult to adjust focusVC-354 board) when focusing is performed when the control button
E6100(Cannot initialize focus.)is pressed in the focus manual mode and inspect the focus motor drive
circuit (IC1501 of VC-354 board) when the focusing is not performed.
Inspect the lens block zoom reset sensor (Pin wh of CN1501 of
Zoom operations faultVC-354 board) when zooming is performed when the zoom switch
E6110
(Cannot initialize zoom lens.)is pressed and inspect the zoom motor drive circuit (IC1501 of
VC-354 board) when the zooming is not performed.
Handshake correction function does not
E6200work well. (With pitch angular velocityInspect angular velocity sensors (SE5201, 5202 of SE-155
board) peripheral circuits.
sensor output stopped.)
Inspect the USB bridge IC (MD-104 board IC4201) and EEPROM
E9300USB bridge IC fault(MD-104 board IC4200)
Fault of writing to or erasing the flash
E9401memoryInspect the flash memory (VC-354 board IC3401) (Note)
Note: Refer to O9. Record of Self-diagnosis c� of O6-3. SERheck VICE
MODE �, ADJ (987676551.pdf).