DCR-DVD201/DVD201E
6. Flange Back Check7. MAX GAIN Adjustment
SubjectSiemens starSetting the minimum illumination.
(2.0m from the front of the lens)If it is not consistent, the image level required for taking subjects in
(Luminance : approx. 200 lux)low illuminance will not be produced (dark).
Measurement PointCheck operation on TV monitorSubjectClear chart
(1.0 m from the front of the lens)
Measuring Instrument
(Note1)
Specified Value Focused at the TELE end and WIDE end.
Adjustment PageF
Note1: The data of page: 0, address: 10 must be O00�.Adjustment Address19
Note1: Shoot the clear chart with the zoom WIDE end. And adjust the
Switch setting:
direction of the camera so that the chart is located in the center of
1) MODE ............................................................. )MOVIE ( the screen.
2) NIGHT SHOT ..................................................................Note2:The data of page: 0, address: 10 must be O00�OFF.
Note3: This adjustment should be carried out upon completion of OFlange
Note2: When the auto focus is ON, the lens can be checked if it is focusedBack Adjustment�.
or not by observing the data on the page 1 of the adjustment remoteNote4: Check that the data of page: 6, address: 02 is O00�. If not, to page:
commander.6, address: 01, set data: 00, and press the PAUSE button.
1) Select page: 0, address: 03, and set data: 0F.Note5: NTSC model : DCR-DVD201
2) Page 1 shows the state of the focus.PAL model : DCR-DVD201E
1 : 00 : XX
Odd: Focused
Switch setting:
Even: Unfocused
1) MODE ............................................................. )MOVIE (
2) NIGHT SHOT ..................................................................OFF
Checking method:
3) ZOOM ....................................................................WIDE end
1) Select page: 6, address: 40, and set data: 01.
2) Select page: 6, address: 41, and set data: 01.4) FOCUS (CAMERA SET menu) ........................... MANUAL
5) DIGITAL ZOOM (CAMERA SET menu) ......................OFF
3) Place the Siemens star 2.0m from the front of the lens.
6) STEADY SHOT (CAMERA SET menu) ........................OFF
4) To open the IRIS, decrease the luminous intensity to the
Siemens star up to a point before noise appear on the image.
Adjusting method:
5) Shoot the Siemens star with the zoom TELE end.
6) Turn on the auto focus.Order Page Address DataProcedure
7) Check that the lens is focused (Note2).100101Set the data.
8) Select page: 6, address: 21, and set data: 10.
2696Set the following data.
9) Shoot the Siemens star with the zoom WIDE end.20 (NTSC), 21 (PAL)
10) Observe the TV monitor and check that the lens is focused.
369700Set the data.
Processing after Completing Adjustments:46016FSet the data, and press PAUSE
1) Select page: 6, address: 21, and set data: 00.button.
2) Select page: 6, address: 40, and set data: 00.5602Check that the data changes to
3) Select page: 6, address: 41, and set data: 00.O01� within 30 sec. (Note6)
4) Select page: 0, address: 03, and set data: 00.
Note6: The adjustment data will be automatically input to page: F, address:
19.
Processing after Completing Adjustments
Order Page Address DataProcedure
169600Set the data.
269700Set the data.
360100Set the data, and press PAUSE
button.
400100Set the data.
6-21 |