MODEL IDENTIFICATIONSAFETY CHECK-OUT
N BACK PANEL N(US model only)
After correcting the original service problem, perform the
following safety checks before releasing the set to the customer:
4-987-Check the antenna terminals, metal trim, Ometallized� knobs, screws,
and all other exposed metal parts for AC leakage. Check leakage as
CDP-CE515described below.
US Model: 842-01
LEAKAGE
CDP-CE515
Canadian Model: 842-11
The AC leakage from any exposed metal part to earth ground and
CDP-CE515
from all exposed metal parts to any exposed metal part having a
AEP Model: 842-21
CDP-C460Zreturn to chassis, must not exceed 0.5 mA (500 microampers).
Leakage current can be measured by any one of three methods.
US Model: 842-31
CDP-CE515
Australian Model: 842-511. A commercial leakage tester, such as the Simpson 229 or RCA
WT-540A. Follow the manufacturersO instructions to use these
instruments.
2. A battery-operated AC milliammeter. The Data Precision 245
digital multimeter is suitable for this job.
3. Measuring the voltage drop across a resistor by means of a
VOM or battery-operated AC voltmeter. The Olimit� indication
is 0.75 V, so analog meters must have an accurate low-voltage
scale. The Simpson 250 and Sanwa SH-63Trd are examples of
a passive VOM that is suitable. Nearly all battery operated
digital multimeters that have a 2V AC range are suitable. (See
Fig. A)
NOTES ON HANDLING THE OPTICAL PICK-UP
BLOCK OR BASE UNITTo Exposed Metal
Parts on Set
The laser diode in the optical pick-up block may suffer electrostatic
breakdown because of the potential difference generated by the
charged electrostatic load, etc. on clothing and the human body.
During repair, pay attention to electrostatic breakdown and also useAC
the procedure in the printed matter which is included in the repair
voltmeter
parts.0.15?F1.5k1(0.75V)
The flexible board is easily damaged and should be handled with
care.
NOTES ON LASER DIODE EMISSION CHECKEarth Ground
The laser beam on this model is concentrated so as to be focused on
the disc reflective surface by the objective lens in the optical pick-Fig. A. Using an AC voltmeter to check AC leakage.
up block. Therefore, when checking the laser diode emission,
observe from more than 30 cm away from the objective lens.
N 3 N |