4.Self-diagnosis Code Table
Self-diagnosis Code
BlockDetailedSymptom/StateCorrection
FunctionCode
Repaired by:
C2100Condensation.Remove the cassette, and insert it again after one hour.
C2200Video head is dirty.Clean with the optional cleaning cassette.
C2300Non-standard battery is used.Use the InfoLITHIUM battery.
LOAD direction. Loading does not
C3110complete within specified timeLoad the tape again, and perform operations from the beginning.
UNLOAD direction. Loading does not
C3111complete within specified timeLoad the tape again, and perform operations from the beginning.
C3120T reel side tape slacking when unloading.Load the tape again, and perform operations from the beginning.
C3121S reel side tape slacking when unloading.Load the tape again, and perform operations from the beginning.
C3122T reel fault.Load the tape again, and perform operations from the beginning.
C3123S reel fault.Load the tape again, and perform operations from the beginning.
C3130FG fault when starting capstan.Load the tape again, and perform operations from the beginning.
C3131FG fault during normal capstan operaLoad the tations.pe again, and perform operations from the beginning.
C3140FG fault when starting drum.Load the tape again, and perform operations from the beginning.
C3141PG fault when starting drum.Load the tape again, and perform operations from the beginning.
C3142FG fault during normal drum operaLoad the tations.pe again, and perform operations from the beginning.
C3143PG fault during normal drum operaLoad the tations.pe again, and perform operations from the beginning.
C3144Phase fault during normal drum operaLoad the tations.pe again, and perform operations from the beginning.
LOAD direction loading motor time-Remove the battery or power cable, connect, and perform
C3210out.operations from the beginning.
C3211UNLOAD direction loading motorRemove the battery or power cable, connect, and perform
time-out.operations from the beginning.
C3220T reel side tape slacking whenRemove the battery or power cable, connect, and perform
unloading.operations from the beginning.
C3221S reel side tape slacking whenRemove the battery or power cable, connect, and perform
unloading.operations from the beginning.
Remove the battery or power cable, connect, and perform
C3222T reel fault.operations from the beginning.
Remove the battery or power cable, connect, and perform
C3223S reel fault.operations from the beginning.
Remove the battery or power cable, connect, and perform
C3230FG fault when starting capstan.operations from the beginning.
C3231FG fault during normal capstanRemove the battery or power cable, connect, and perform
operations.operations from the beginning.
C3240FG fault when starting drum.Remove the battery or power cable, connect, and perform
operations from the beginning.
C3241PG fault when starting drum.Remove the battery or power cable, connect, and perform
operations from the beginning.
FG fault during normal drumRemove the battery or power cable, connect, and perform
C3242operations.operations from the beginning.
PG fault during normal drumRemove the battery or power cable, connect, and perform
C3243operations.operations from the beginning.
Phase fault during normal drumRemove the battery or power cable, connect, and perform
C3244operations.operations from the beginning.
N 8 N |