1-1-3. Preparations
Note 1:For details of how remove the cabinet and boards, refer to O2.
DISASSEMBLY�.
Note 2:When performing only the adjustments, the lens block and boards
need not be disassembled.Pattern box
1) Connect the equipment for adjustments according to Fig. 5-1-3.
2) By setting the OForced Camera Power ON mode�, the camera
power can be turned ON even if the front panel block (MA-
351 board, power switch, microphone unit) has been removed.
When removing the front panel block disconnect the following
connector.1.5 m
1. VC-214 board CN903 (20P 0.5mm)
Note 3:As removing the cabinet (R) (removing the VC-214 board CN911)
means removing the lithium 3V power supply (CF-56 board
BH001), data such as date, time, user-set menus will be lost. After
completing adjustments, reset these data. If the cabinet (R) has
been removed, the self-diagnosis data, data on history of use (total
drum rotation time etc. ) will be lost. Before removing, note down
the self-diagnosis data and data on history use (data of page: 2,
address: A2 to AA). (Refer to OSELF-DIAGNOSIS FUNCTION�Front of the lens
for the self-diagnosis data, and to O5-4. Service Mode� for the
data on the history use.)
Note 4:Setting the OForced Camera Power ON� ModeFig. 5-1-2.
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 01, and press the PAUSE
button of the adjustment remote commander.
The above procedure will enable the camera power to be turned
on with the front panel block removed. After completing
adjustments, be sure to exit the OForced Camera Power ON
Mode�.
Note 5:Exiting the OForced Camera Power ON� Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 00, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 0, address: 01, and set data: 00.
5-3 |