Note 3: Setting the Oforced camera power supply ON mode�1-1-2. Preparations
1) Set data: 01 to page: 0, address: 01.Note 1: Refer to OSection 2 DISASSEMBLY� for details of
2) Set data: 21 to page: D, address: 10, and presshow to remove the cabinet and boards.
the PAUSE button of the adjusting remoteNote 2: If performing only adjustments, the lens block and
commander.VC-190 board need not be adjusted.
The camera power supply can be turned ON even if the cabinet1) Connect the adjusting equipment according to Fig. 5-1-3,
(R) has been removed using the above steps. After completing4.
adjustments, be sure to exit the Oforced Camera power supply2) The front panel block (MI-27/MI-28/MA-298 boards) need
ON mode�.not be connected.
Note 4: Exiting the Oforced camera power supply ON mode�To remove, disconnect the following connector.
1) Set data: 01 to page: 0, address: 01.1. CN303 (26P, 0.5 mm) of MI-27/28 board (3.5"
2) Set data: 00 to page: D, address: 10, and pressLCD/4" LCD model)
the PAUSE button of the adjusting remoteCN303 (14P, 0.5 mm) of MA-298 board (2.5"
commander.LCD model)
3) Set data: 00 to page: 0, address: 01.(Refer to pages 5-58 for the Arrangement Diagram for
Adjustment Parts.)
3) The accessory shoe need not be connected.
To remove, disconnect the following connector.
1. CN205 of VC-190 board (10P, 0.5 mm)Pattern box
(Refer to pages 5-92 for the Arrangement Diagram for
Adjustment Parts.)1.5m
4) The viewfinders (VF-111, 112 boards (COLOR EVF
model), VF-99/102 board (B/W EVF model) need not be
connected. To remove, disconnect the following
connector.Front of lens
1. CN111 of VC-190 board (20P, 0.5 mm)
(Refer to pages 5-58 for the Arrangement Diagram for
Adjustment Parts.)
5) By setting the Oforced power supply ON mode�, the
camera power supply can be turned ON even if the cabinet
(R) (power switch, speaker, SD-27/28 board) has been
removed. When removing the cabinet (R), disconnect theFig. 5-1-2.
following two connectors. However, as removing CN1953
means removing the lithium 3V power supply, data such
as date, time, user-set menus will be lost. After
adjustments, reset these data. If CN1953 has been
removed, the self-diagnosis data, data on history of use
(total drum rotation time, date of when the user first
turned the power ON, and the date of when condensation
occurred the last time) will be lost. Before removing, note
down the self-diagnosis data and data of page:3,
address:E0 to E9. (Refer to the OService Mode� of
OVIDEO SECTION ADJUSTMENTS� for the data on the
history of use.)
1. CN1950 of VC-190 board (28P, 0.5 mm)
2. CN1953 of VC-190 board (28P, 0.5 mm)
(Refer to pages 5-58 for the Arrangement Diagram for
Adjustment Parts.)
After the adjustments, be sure to exit the Oforced camera
power supply ON mode�.
5-3 |