12. IRIS IN/OUT adjustment
Purpose :Measure the light level and write into EE
PROM for indoor/outdoor identification in auto
white balance.
Adjustment error :Incorrect white balance.
SubjectWhite pattern standard picture frame
Measurement Point
EVF or DDS display of monitor TV
Measuring Instrument
Adjustment PageF
50
Adjustment Address
51
Note 1 :Confirm that the OCamera-shaking� correction to OFF.
(EXCEPT TRV14E MODEL)
Note 2 :Confirm that the ODigital Zoom� is turned OFF.
(EXCEPT TRV14E MODEL)
Adjustment procedure:
OrderPageAddressDataProcedure
160001After setting the data, press the PAUSE button.
(Preparation)
2F0221After setting the data, press the PAUSE button.
3Turn off the UNREG power supply once, then turn it on.
460001After setting the data, press the PAUSE button.
5611Confirm that the date is 00.
66014BAfter setting the data, press the PAUSE button.
760149After setting the data, press the PAUSE button.
8611If data is 01, this is the end of data read. The data of page F,
address 50 and 51 are automatically input to this memory.
Processing after Adjustments:
OrderPageAddressDataProcedure
160100After setting the data, press the PAUSE button.
2F0200After setting the data, press the PAUSE button.
3Turn off the UNREG power supply once, then turn it on.
460000After setting the data, press the PAUSE button. (End)
6-20 |