3-1-6. Input/Output Level and Impedance3-1-8. Service Mode
Video outputPhono jack, 1 W ,Vp-p, 75Additional note on adjustment
unbalanced, sync negativeNote:After the completion of the all adjustments, cancell the ser-
Audio outputPhono jack,vice mode by either of the following ways.
Output: �7.5 dBs, (at load impedance 47 kW ),
impedance less than 2.2 kW1) Unplug the main power supply and remove the lithium battery.
(In this case, date and time and menu setting have been set by
users are canceled. Perform resetting.)
2) After data on page: D and F is restored, select page: 0, address:
3-1-7. Recording Mode (Standard 8/Hi8) switching01, and return the data to 00. And when data on page: 3 is changed,
(Hi8 model)return the data to the original condition.
The record mode (Standard 8/Hi8) of this unit switches as shown in
the following table. The playback mode (Standard 8/Hi8) switc1. Test mode settinghes
automaticaly according to the recording mode of the tape playedSet/release each test mode. Select page: 0, address: 01, and set data:
back.01 before setting the data of page D and F.
Page FAddress 2A
Tape UsedRecording Mode
MEHi8DataFunction
Hi8 MP
MPStandard 800Normal
Test mode
Various emergency prohibitions and releases
01Drum emergency, capstan emergency, loading motor
emergency, reel emergency, tape top and end, DEW
detection
Page DAddress 10
DataFunction
00Normal
01Camera power ON
02VTR power ON
03Camera+VTR power ON
* For page D and F, the data set will be recorded in the nonvolatile
memory by pressing the PAUSE button on the adjusting remote
commander. Take note that, in this case, the test mode will not
be released even if the main power has been turned off (8.4 Vdc).
* Be sure to return this address data to 00 after completing adjust-
ments/repairs and press the PAUSE button of the adjusting re-
mote commander. And select page: 0, address: 01, and set data:
00.
5-40 |