9. Auto White Balance Standard Data Input10. Auto White Balance Adjustment
Adjust to the proper auto white balance output data.
SubjectClear chartIf it is not correct, auto white balance and color reproducibility will
(Color bar standard picture frame)be poor.
Adjustment PageF
Adjustment Address70 to 73SubjectClear chart
(Color bar standard picture frame)
Note 1:Perform OColor Reproduction Adjustment� before thisFilterFilter C14 for color temperature
adjustment.correction
Note 2:Check that the data of page: 2, address: 02 is 00. If not,Measurement PointDDS display of EVF or TV monitor
turn the power of the unit OFF/ON.Measuring Instrument (Note 1)
Switch setting:
1) NIGHT SHOT switch...................................................... OFFAdjustment PageF
Adjustment Address3A, 3B
Adjusting method:Specified ValueR ratio: 2B40 to 2BC0
1) Select page: 0, address: 01, and set data: 01.B ratio: 5E40 to 5EC0
2) Wait for 2 seconds.
3) Select page: 2, address: 01, and set data: 11, and press the PAUSENote 1:Perform OAuto White Balance Standard Data Input� before
button of the adjusting remote commander.this adjustment.
4) Select page: 2, address: 01, and set data: 0D, and press the PAUSENote 2:The right four digits of the display data at the right bottom
side of the EVF and TV monitor is the object data.
button of the adjusting remote commander.00 XXXX
(When the standard data is take in, the data will be automaticallyn Object data
input to page: F, address: 70 to 73.)Switch setting:
5) Select page: 2, address: 02, and check that the data is O01�.1) NIGHT SHOT switch ...................................................... OFF
6) Perform OAuto White Balance Adjustment�.
Adjusting method:
Processing after Completing Adjustments1) Place the C14 filter for color temperature correction on the lens.
1) Select page: 2, address: 01, and set data: 00, and press the PAUSE2) Select page: 0, address: 01, and set data: 01.
button of the adjusting remote commander.3) Select page: D, address: 11, and set data: 02, and press the
2) Select page: 0, address: 01, and set data: 00.
PAUSE button of the adjusting remote commander.
4) Select page: 2, address: 01, and set data: 3F, and press the PAUSE
button of the adjusting remote commander.
5) Select page: 0, address: 03, and set data: 04.
6) Select page: F, address: 3A, and change the data, and adjust the
average value of the DDS display data(Note 2) to the R ratio
specified value.
7) Press the PAUSE button of the adjusting remote commander.
8) Select page: 0, address: 03, and set data: 05.
9) Select page: F, address: 3B, and change the data, and adjust the
average value of the DDS display data(Note 2) to the B ratio
specified value.
10) Press the PAUSE button of the adjusting remote commander.
Processing after Completing Adjustments
1) Select page: D, address: 11, and set data: 00, and press the
PAUSE button of the adjusting remote commander.
2) Select page: 0, address: 01, and set data: 00.
3) Select page: 2, address: 01, and set data: 00, and press the PAUSE
button of the adjusting remote commander.
4) Select page: 0, address: 03, and set data: 00.
5-19 |