2. Emergency Memory Address2-1. EMG CODE (Emergency Code)
The codes shown in the following table which correspond to errors
Page FAddress 10 to 1B
that occur are recorded in addresses 10, 14, and 18.
AddressContentsCodeType of Emergency
101st EMG code00No error
Upper: MSW code when the mechanism starts shifting10Loading motor time-out during load
12the 1st time11Loading motor time-out during unload
Lower: MSW code when the 1st emergency occur20sT reel emergency (reel slack) during unloading
13Lower: Target MSW code of the 1st emergency occur21sS reel emergency (reel slack) during unloading
142nd EMG code22T reel emergency
Upper: MSW code when the mechanism starts shifting23S reel emergency
16the 2nd time30FG emergency at the start up of the capstan
Lower: MSW code when the 2nd emergency occur31sFG emergency during the normal rotation of the capstan
17Lower: Target MSW code of the 2nd emergency occur40 sFG emergency at the start up of the drum
18Last EMG code41PG emergency at the start up of the drum
Upper: MSW code when the mechanism starts shifting42FG emergency during the normal rotation of the drum
1Athe last time43PG emergency during the normal rotation of the drum
Lower: MSW code when the last emergency occursPhase emergency during the normal rotation of the
44
1BLower: Target MSW code of the last emergency occurdrums
When there are no emergency, data 00 will be written in the above
addresses (10 to 1B). When the first emergency occurs, the data
corresponding to the emergency will be written in the address (10
to 13) for this first emergency. In the same way, when the second
emergency occurs, the data corresponding to the emergency will be
written in the address (14 to 17) for this second emergency.
The data corresponding to the emergency occurring the last will be
written in the address (18 to 1B) for this last emergency.
Therefore the data of addresses 18 to 1B are renewed each time an
emergency occurs.
Note 1:Be sure to rewrite the data of addresses 10 to 1B to 00
after repairs/adjustments.
Note 2:When rewriting the data, be sure to press the PAUSE
buttton of the remote commander after setting the data.
5-31 |