2-9. SERVICE POSITION-2 (For voltage measurement-2)
Firstly, remove the following parts referring DISASSEMBLY (sections 2-1, 2-2, 2-3, and 2-7), and connect parts as shown below.
Regulated DC power supply
(DC +3 V)
Fix the battery case OPEN/CLOSE
sensor switch to the "ON" position Power supply cord jig
with adhesive tape.(J-6082-415-A)
VC-205 board (CN801)
POWER ON/OFF switch
Cabinet (upper) assembly
VC-205 board
Cartridge
CD-191 board
MJ-88 board
Extension jig (J-6082-426-A)
VC-205 board (CN101)
Cabinet (rear) assembly
2-7 |