1-6. Replacement of Main Parts
1-7.Notes on Service
1-8.Optional Cables
1-9.Tool
6. DC-DC assy installation1-7-2.Notes on Replacement of V Shoe
Attach the DC-DC assy in the reverse way of removal
steps.It is necessary to attach the V shoe on the chacking plate
7. Inside panel installationwith precisely position when will attach the CA-705 on the
Install the inside panel with three csrews.DVW-700 in absolute contact.
Tighten the three screws sequentially in the figure when
attach the V shoe on the chacking plate. Make sure that the
1-7. Notes on Serviceplane A (shown in the figure) is in absolute contact with the
installation part when attach the CA-705/705P on the
1-7-1.Power Circuit BreakerDVW-700/700WS/700P/700WSP and tighten the two coin
screws.
Excessive current in the internal circuitry, whatever the
cause, will trip the internal circuit breaker, automaticallyCoin screws
cutting off the power. After checking that the problem hasPlane APlane A
been corrected, press the button shown in the figure. The
power should come on again.
1
2
3
Breaker release button
1-8. Optional Cables
ill 1-7-2
TRIAX cable
ill 1-7-1KINGS type (for NTSC)FISCHER type (for PAL)
CCT-50 (50 m)CCT-K50 (50 m)
CCT-100 (100 m)CCT-K100 (100 m)
CCT-150 (150 m)CCT-K150 (150 m)
CCT-300 (300 m)CCT-K300 (300 m)
They are used for connecting the CCU-355/355P to the CA-
705/705P.
1-9. Tool
Extension board EX-454 : J-6258-670-A