Section 1
Installation
1-1. Operating Environment1-2-2. Recommended Power Cord
Operating temperaturedC to +:450dCFor customers in the U. S. A. and Canada
Performance temperature+5dC to :+40dCRequired Part
Humidity: 10 % to 90 %
1 Power Cord, 125 V 10 A (2.4 m)
: 1-557-377-11
(No condensation)2 Plug Holder (Black)
: 2-990-242-01
Mass: approx. 3 kg
For obtaining, contact your local Sony sales office
/ service center.
To prevent overheating of the unit ensure that there is goodAC inlet
12
air circulation around the unit.
Select an installation place as operating temperature of the
unit is 5 dC to 40 dC. Do not place the unit near heart
sources.
For customers in the United Kingdom
Required Part
1-2. Power Supply
1 Power Cord, 250 V 10 A (2.4 m)
: DK-2401 (UK)
2 Plug Holder (Black): 2-990-242-01
A switching regulator (+5 V) is used for the power source1
of the unit. So the unit can be used with a voltage of 100 VAC inlet
2
to 240 V ? 10 % without changing the input supply
voltage.
1-2-1. Power Supply Specifications
For customers in the Europe
Power voltageAC 100 to 240 V ? 10 %
Required Part
Power frequency50 or 60 Hz
Power consumption10W1 Power Cord, 250 V 10 A (2.4 m)
: DK-2401 (AE)
2 Plug Holder (Brown): 3-613-640-01
Rush Current17 A (120 V)
1
28 A (240 V)
AC inlet
2
w
Use the specified power cord only.
Be sure to use the recommended power cord to avoid fire
and/or an electric shock.
c
Ground the unit for safety.
Be sure to attach a ground wire to avoid an electric shock.
n
If the unit is used in the area except above, contact your
local Sony sales office / service center.
BKS-R1607/R1608
BKS-R3209/R32101-1(E) |