2-3. ISR
2-3. ISR
When this board is installed in combination with the BKPF-500 ISR (Interactive Status Reporting)
interface board in a digital video interface unit, such as the PFV-D20/D50/D100A/D200A, the following
messages are sent to the ISR system, permitting the operating status of the BKPF-132BP to be monitored.
Refer to the Operation and Maintenance Manual of the BKPF-500 for details.
Y Status Messages (Error/Warning Messages)
MessageDescription
NO INPUTIndicates that no signal is input or the input signal is not judged to be contained.
Otherwise, indicates that the free-running switch (S1) is set to ON.
NO REFERENCEIndicates that a reference timing signal is not supplied for some reason. However,
this message is not displayed when the LOCK MODE switch (S6) is set to INPUT.
OUT OF SYNCHRO RANGE Indicates when the phase of the signal input to the SDI IN connector is out of the
sync range. However, this message is not displayed when the LOCK MODE switch
(S6) is set to INPUT, when no reference signal is input or when the message is "NO
INPUT".
Y Setup Messages
MessageStatus Display *1Description
SYSTEM H PHASE[***] HEXIndicates the setting of the SYSTEM H PHASE (system phase)
adjustment (S9, S10).
LOCK MODEINPUTIndicates the setting of the LOCK MODE switch(S6). *2
REF IN
SYNCHRO MODE0HIndicates the setting of the SYNCHRO MODE switch(S11). *3
1H DELAY
2H DELAY
INPUT
*1 :Status information displayed after the message. [***] indicates a variable.
*2 :The status display appears as OINPUT� irrespective of S6 setting when a reference signal is not
input.
*3 :The status display appears as OINPUT� irrespective of S11 setting when the LOCK MODE switch is
set to INPUT or when no reference signal is input.
2-2BKPF-132BP |