CHAPTER 10 EXTERNALS/AUXILIARY MECHANISMS
? FM6
4. Laser Scanner Motor Cooling Fan
1) Open the front cover.
? FM5
2) Release the feeding assembly lever and
1) Open the front cover.
the developing assembly lever.
2) Remove the inside cover.
3) Remove the screw [1], and detach the
3) Disconnect the connector [1], remove the
drum cartridge [2].
wire saddle [2], and remove the screw;
then, detach the laser scanner motor
cooling fan (FM5) together with its cover.[2]
[1]
[5]
[4]
Figure 10-535
4) Disconnect the connector [3], and remove
the screw [4]; then, slide out the drum
cartridge stay [5] to the front.
(At this time, take care so that the rear of
the stay will not come into contact with
the developing cylinder.)
[5][3]
[1]
[3][2]
Figure 10-534
Caution:
When mounting the fan, be sure that the
marking (arrow indicating the direction
of air current) and the marking on the fan
will match.
[3]
[4]
Figure 10-536
10-28COPYRIGHT ? 1999 CANON INC. CANON 405/335 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON) |