Service Menu
Service Submenu1 Service Submenu2 Factory Settings
Dclock Polarity Falling Init NVM Country ***
UOC Hposition * Initial APS off Language ***
ADC_Calibration Hotel Mode Activate off Panel Type SAMSUNG 15_XGA
UOC_Calibration Burn-In Mode off Menu Background Opaque
** Remote Control ***
PC Mode on
* This value indicates the horizontal positioning of the picture.
** In this row ?Software version and date is mentioned?
*** These will be changed according to the DI.
" It is possible to move by using ?UP?, ?DOWN?, ?LEFT? and ?RIGHT? RC buttons in this menu
structure.
4.2.1. UOC Horizontal Position
" Press ?DOWN? RC button at ?Service Submenu 1? to highlight ?UOC Hposition?
" Set the proper value to fit the applied pattern to screen by using ?LEFT? and ?RIGHT? buttons.
4.2.2. UOC Calibration
" Apply 11 Vertical bar Grey-scale pattern with black on the left and white on the right side of
the picture (as seen below) from CVBS input.
" Press RC ?AV? button, and switch to CVBS input and observe the pattern applied.
" Enter to PW1306 service menu.
" Press RC ?DOWN? button at ?Service Submenu 1? and highlight ?UOC Calibration?.
" Press RC ?RIGHT? button to start calibration.
4.2.3. PW1306 PC Input ADC Calibration
" Connect your TV with your PC and press RC ?PC? button and observe the image.
" Press ?M? to display Menu and select ?Options? by using right button of RC.
" Press ?Down? button of the RC and activate ?auto adjustment?.
" Press right button of the RC to perform ?auto adjustment? and press ?M? to exit from Menu.
" Apply black on the left, white on the right (as seen below) XGA@60Hz (1024x768) pattern
from PC.
" Enter PW1306 service menu as described above.
" Press RC ?DOWN? button at ?Service Submenu 1? and highlight ?ADC Calibration?.
" Press RC ?RIGHT? button to start calibration.
38
15? TFT TV Service Manual |